6 en | Delivery Status RAID Subsystem DVA-08K and DVA-16K | Quick Installation Guide
F.01U.027.800 | V1 | 2006.05 Bosch Security Systems
2 Delivery Status
The subsystems are shipped with drives pre-configured for RAID 5. The configuration is suit-
able for the most configurations. The factory default settings are shown below.
2.1 RAID Settings
2.2 System Settings
DVA-08K DVA-16K
Number HDD 4 8 16
RAID RAID 5 RAID 5 RAID 5
Spare nonono
Stripe Size 16 16 16
Partitions 1 2 4
Size of Partition (est.) 1.5 TB 50% (1.7 TB) 25% (1.875 TB)
Assigned Disk Space 470000 MB 470000 MB 470000 MB
SCSI Channel 0 0 0
SCSI IDs 0 0, 1 0, 1, 2, 3
LUN 0 0, 0 0, 0, 0, 0
Table 2.1 Factory Default settings DVA-08K/DVA-16K
Menu DVA-08K/DVA-16K
Configuration Parameters/Communication
LAN 0 Static IP Address
IP Address 10.11.12.13
Subnet 255.0.0.0
Configuration Parameters/Controller
Write-Back Cache Enabled
Optimization Sequential I/O
Sync Period (Sec.) Disabled
SDRAM ECC Enabled
Configuration Parameters/Host Side
Maximum Queued I/O Count 256
LUNs per Host SCSI ID 1
Maximum Concurrent Host-LUN Connection Default (4)
Tags Reserved per Host-LUN Connection Default (32)
Peripheral Device Type Default 7F (no device present)
Peripheral Device Qualifier Default (Connected)
Device Supports Removable Media Default (Disable)
LUN Applicability All Undefined LUNs
Cylinder/Head/Sector Default (Variable/Variable/Variable)
Configuration Parameters/Drive Side
Disk Access Delay Time (Sec.) 25
Table 2.2 System settings DVA-08K/DVA-16K
Comentarios a estos manuales