INSTALLATION & USER INSTRUCTIONS
INTELLIGENT ROOM THERMOSTAT
FR 10
6 720 613 547-00.1R
FOR USE WITH THE FOLLOWING APPLIANCES:
GREENSTAR CDI COMBINATION BOILERS
GREENSTAR CDI SYSTEM BOILERS FITTED WITH OPTIONAL
INTEGRAL DIVERTER VALVE
GREENSTAR HIGHFLOW CDI COMBINATION BOILERS
6 720 617 760 (2008/09)
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - INTELLIGENT ROOM THERMOSTAT

INSTALLATION & USER INSTRUCTIONSINTELLIGENT ROOM THERMOSTATFR 106 720 613 547-00.1RFOR USE WITH THE FOLLOWING APPLIANCES:GREENSTAR CDI COMBINATION

Pagina 2 - Dear customer

10Installation (for installers only)6 720 617 760 (2008/09)B Select the installation location.Fig. 26 720 612 218-02.1J1,0 m1,2 m0,75 m85 mm100 mm35 m

Pagina 3 - Contents

11Installation (for installers only)6 720 617 760 (2008/09)B Remove the top section from the base.Fig. 3The mounting surface on the wall should be lev

Pagina 4 - 1.1 Symbols

12Installation (for installers only)6 720 617 760 (2008/09)B Fit the base.Fig. 4B Connect to the power supply.Fig. 5B Push on top section.6 720 612 21

Pagina 5 - 1.2 Safety precautions

13Installation (for installers only)6 720 617 760 (2008/09)3.2 DisposalB Dispose of packaging in an environmentally responsible man-ner.B When replaci

Pagina 6

14Commissioning (for installers only)6 720 617 760 (2008/09)4 Commissioning (for installers only)1 Switch on the system.2 During first commissioning o

Pagina 7 - 2.2 Technical data

15Operation6 720 617 760 (2008/09)5 OperationFig. 66 720 613 554-02.1Rmode21

Pagina 8 - 2.4 Cleaning

16Operation6 720 617 760 (2008/09)The FR 10 can only regulate the heating system if an operating mode is enabled. In conjunction with a time switch (a

Pagina 9 - 3.1 Installation

17Operation6 720 617 760 (2008/09)5.1 Changing the operating modeB Briefly press mode until the required operating mode is dis-played. = constant Comf

Pagina 10 - 6 720 617 760 (2008/09)

18Operation6 720 617 760 (2008/09)5.3 Changing the standard setting of the required room temperature B Accessing user level: Hold down mode for approx

Pagina 11 - 6 720 612 218-04.1R

19Operation6 720 617 760 (2008/09)B Briefly press to save the value.B Press mode until the current room temperature is displayed.5.4 Adjusting the i

Pagina 12 - Heatronic 3

2Dear customer,6 720 617 760 (2008/09)Dear customer,Congratulations on having decided in favour of a top-quality prod-uct from our company. The FR 10

Pagina 13 - 3.3 Electrical connections

20Operation6 720 617 760 (2008/09)5.4.1 Changing the code (parameter: 5A p)Setting range: 1 to 10Use this parameter if you want to adjust the code aft

Pagina 14

21Operation6 720 617 760 (2008/09)5.4.3 Adjusting the room temperature sensor (parameter: 6A p)Setting range: – 3.0 °C (K) to +3.0 °C (K)Use this par

Pagina 15 - 6 720 613 554-02.1R

22Operation6 720 617 760 (2008/09)5.4.5 Selecting amplification factor V (parameter: 6C p)Setting range: 40 % to 100 %Subject to changes in room tempe

Pagina 16

23Operation6 720 617 760 (2008/09)5.5 Selecting the heating program B Select the heating program with start and stop switching times at the time switc

Pagina 17

24Troubleshooting6 720 617 760 (2008/09)6TroubleshootingIf the boiler has developed a fault, the display will show, for exam-ple, EA. E. Here, EA mean

Pagina 18

25Troubleshooting6 720 617 760 (2008/09)Fault Cause RemedyRequired room temperature not achieved.Thermostatic valve(s) are not opened sufficiently.Ful

Pagina 19

26Troubleshooting6 720 617 760 (2008/09)If the fault persists:B Call your installer or customer service and inform them of the fault, quoting the appl

Pagina 20

27Tips on saving energy6 720 617 760 (2008/09)7 Tips on saving energy • Regulate the temperature in adjacent rooms via thermostatic valves.• External

Pagina 21

28Environmental protection6 720 617 760 (2008/09)8 Environmental protectionEnvironmental protection is a fundamental corporate strategy of the Bosch G

Pagina 22

296 720 617 760 (2008/09)Notes

Pagina 23 - 5.6 Frost protection

3Contents6 720 617 760 (2008/09)Contents1 Symbols and safety precautions . . . . . . . . . . . . . . . . . . . . 41.1 Symbols . . . . . . . . . . . .

Pagina 24 - 6Troubleshooting

306 720 617 760 (2008/09)Notes

Pagina 25 - Troubleshooting

316 720 617 760 (2008/09)Notes

Pagina 26

Dedicated to heating comfortWorcester, Bosch GroupCotswold Way, Warndon, Worcester WR4 9SWTel. 01905 754624 Fax. 01905 754619Worcester, Bosch Group is

Pagina 27 - 7 Tips on saving energy

4Symbols and safety precautions6 720 617 760 (2008/09)1 Symbols and safety precautions1.1 SymbolsSignal words indicate the seriousness of the hazard i

Pagina 28 - 8 Environmental protection

5Symbols and safety precautions6 720 617 760 (2008/09)1.2 Safety precautionsB These instructions must be observed to ensure correct opera-tion.B Insta

Pagina 29

6Technical data for the accessory item6 720 617 760 (2008/09)2 Technical data for the accessory item• The FR 10 enables the room temperature control o

Pagina 30

7Technical data for the accessory item6 720 617 760 (2008/09)2.1 Standard packageFig. 11 Top section, controller and base for wall mounting2 Installat

Pagina 31

8Technical data for the accessory item6 720 617 760 (2008/09)2.3 Supplementary accessories• MT 10: Mechanical single channel time switch.• DT 20: Twin

Pagina 32 - CONTACT INFORMATION

9Installation (for installers only)6 720 617 760 (2008/09)3 Installation (for installers only)3.1 InstallationThe installation location must be suitab

Comentarios a estos manuales

Sin comentarios