GV4 Series Control Panel | Release Notes
8 Bosch Security Systems, Inc. | 11/11 | F01U261045-01
Keypads assigned to an area with the A# Two Man
Rule set to Yes must be configured for Area Wide
Scope (CC# Scope set to Area).
When the A# Two Man Rule set to Yes no keypads in
the system can be assigned to Panel Wide Scope (CC#
Scope must not be set to Panel Wide).
When the A# Two Man Rule set to Yes no keypads in
the system with Account Wide or Custom Scope (CC#
Scope set to Account or Custom) can include an area
with A# Two Man Rule set to Yes in their scope.
Set A# Early Ambush to No for areas with the A# Two
Man Rule set to Yes.
Failure to follow the additional configuration
requirements shown above will result in
unintended system behavior.
The D720 Keypad does not support the Two-
Man Rule feature.
The Two-Man Rule feature is not allowed for
use in SIA CP-01 compliant installations.
Consult the local authority having jurisdiction
(AHJ) for proper usage. Refer to your control
panel’s entry guide for programming
information.
3.1.1 Sensor Reset Command (COMMAND
47)
O
n the D1260 and D1260B Keypads, when
the Sensor Reset command (COMMAND 47)
is executed, Call for Service appears
erroneously on the display for a brief time.
This effect also occurs when the control panel
reboots.
3.1.2 ANSI SIA CP-01
Change
the Service Passcode (User ID 0)
factory default value when the ANSI SIA CP-
01 required Passcode Length parameter is 4
or greater.
3.1.3 ITS-DX4020-G
When using
an ITS-DX4020-G as a GSM phone
device, the central station phone number
must have a dial pause (C) option as the first
digit.
3.1.4 Single RPS Connection
Only one connection to
RPS can be made.
RPS does not notify you if you are already in a
connection.
3.1.5 Area Assigned
When c
onfiguring a custom area scope for a
keypad, always include the Area Assigned.
Failure to do so results in inconsistent
operation.
3.1.6 COMMAND 7 and COMMAND 9
Bosch r
ecommends that COMMAND 7 and
COMMAND 9 be configured to not require a
passcode. When an alarm is sounding, any
passcode entry for any command will silence
all alarms in all areas in which the user has
authority.
If a low-priority alarm is within its abort
window and the alarm bell timer expires, the
keypad annunciation will persist unexpectedly
beyond the bell timeout. The keypad must be
manually silenced with a valid passcode.
4.0 Upgrading to a GV4 Series
Control Panel
RPS Accounts Upgrade
RPS version 5.14 or newer is required to upgrade
an existing G Series or GV2 Series Control Panel
installation to a GV4 Series Control Panel. Refer
to the RPS help files for the specific control panel
for additional information on control panel
conversion. In the RPS help file, select:
Panel Specific InformationCommunicating
with 9000 Series PanelsUpgrading a Panel
Type
Hardware Upgrade
The GV4 c
ontrol panel's terminal blocks, SDI
quick-connect terminal, and accessory
connector are all fully compatible with all G
series and GV2 series control panel
peripherals.
The D5200 Programmer is not compatible
with the GV4 Series control panel.
On-board Relays B (Terminal 7, labeled Alt
Alarm) and C (Terminal 8, labeled SW Aux)
are now installed in the factory. No
supplemental installation or purchase is
necessary to prepare these terminals for use.