Application Note
BlueBox Demo-Board for the digital sensors
SMB365 (acceleration) and SMD500 (pressure)
Bosch Sensortec
AN18002
Rev. 1.0
Page 31
© Bosch Sensortec GmbH reserves all ri
g
hts even in the event of industrial propert
y
ri
g
hts. We reserve all ri
g
hts of disposal such
cop
y
in
g
and passin
g
onto third parties.
7211RB11.
Settings Æ Measurements
According to customized settings (high signal resolution or low power consumption) it is
possible to choose different sample averaging numbers and update rates. E.g. increasing the
resolution leads to a decreased noise with increased power consumption and contrariwise. This
behavior can be edited by the following:
4.
Open Settings Æ Measurements
5.
The following message box appears
6.
Chose sampling average number and update rate according to the text
sampling average number = Number of single values for avg. calculation
o edit by mouse scroll
update rate = time for a new “send data command”
o Minimum update rate 0.5 s
sample rate = update rate / sampling average number
o Minimum sampling rate 0.1 s