Bosch Sicherheitssysteme GmbH Operation Manual F.01U.033.372 | V5 | 2009.09
3.4 The Device List
The device list is located on the left-hand side of the screen.
Depending on what is selected, the following are displayed:
Configured cameras and/or DiBos devices
Favorites view
Incoming alarms.
Configured cameras and/or DiBos devices
All locally connected cameras are listed.
If remote stations have been configured, they are listed along
with the cameras connected to them.
Network remote stations are automatically connected to the
local system.
DiBos device (localhost or remote station)
Right-click the icon to call up the following commands:
Connect
Creates the connection to the DiBos device.
Disconnect
Disconnects the connection to the DiBos device. The
DiBos device remains disconnected (even after a reboot),
until it is reconnected manually.
RAS remote stations must likewise be connected manually.
Configuration
With localhost: the default configuration opens.
With remote stations: the configuration opens in remote
mode.
Display all cameras
Displays all the DiBos device cameras in the image area.