48 en | Appendix: Technical Specifications RAID Subsystem DVA-08K | Installation Manual
F.01U.027.797 | V1 | 2006.05 Bosch Security Systems
7.1 Controller Specifications
7.1.1 Configuration
Safety Requirements
UL
CB
Shock
Half-sine Operating: 5G peak, 11ms duration
Non-operating: 15G, 11ms, half-sine
Vibration
Operating 0.5oct/min
Non-operating 0.5oct/min
Warning Alarms
• LCD screen messages
• Audible alarms
• System LEDs
• Event notification via the Bosch RAIDWatch Manager (LAN broadcast, email, fax,
MSN, ICQ, SMS, and SNMP traps) and RS-232C terminal display
Specifications
RAID Levels 0, 1(0 + 1), 3, 5, 10, 30, 50, JBOD, and non-RAID disk spanning
Host OS Compatibil-
ity
Host OS independent; supports all major platforms
Host Interface 2 SCSI-320 channels via 2 dual-stacked VHDCI connectors
Host Channels 2 pre-configured SCSI-320 host channels
Drive Interface Supports 8 channel connection to 3Gbps SATA-II disk drives,
SATA-I backward compatible
Drive Channels All drive channels are pre-configured, routed through a back-end
PCB and cannot be changed