PK32 Programming Key
The D4412 Control Panel uses the PK32 Programming
Key to copy one control panel's programming to
another control panel. Installers can use the PK32
Programming Key as a template. For example, an
installer could store a residential template in one PK32
and a commercial template in another PK32. A light
emitting diode (LED) lights to indicate when
information is sent to or from the PK32 Programming
Key, and the LED blinks when functional diagnostics
are performed on the PK32 Programming Key.
Keypads
The D4412 Control Panel supports LED, liquid crystal
display (LCD), and vacuum fluorescent (VF) keypads.
It requires a D623 Series Keypad or a D625 Series
Keypad for local system programming or for use as an
installer's keypad.
On a keypad, enter a passcode followed by a function
key to perform functions such as arming and disarming
the system or resetting the smoke detectors. The
supported keypads provide new users with easy to
follow procedures, and provide expert users quick
access.
Communications Formats
The D4412 Control Panel works with most alarm
receivers on the market. It supports Contact ID,
Modem IIIa
2
, and Basic Pager communication formats.
The Basic Pager format allows control panels to dial a
digital pager service and leave a numeric message
representing the account number, event number, area
number, and point or user number.
Routing Destinations
The D4412 Control Panel has two routing destinations
for reports. It routes by point and report group to the
destinations. You can send alarm reports for one point
to Destination 1, and send alarm reports for another
point to Destination 2. Each destination has two
programmable 32-digit phone numbers, and there is a
programmable answering machine bypass function. No
external hardware is required.
Event History Log
The event history log stores up to 254 events in non-
volatile memory. You can read the log at a compatible
keypad or upload it to RPS. The event history log
stores a list of open or close events, alarms, and
troubles. Area, point (device), user, and
communication information relevant to each event is
also tracked. The event history log organizes the
information by time and date.
Scheduled Events (Skeds)
Skeds are programmable events that occur at a
specific time and on a specific day. These events
include Auto All On, Auto Part On, Auto Part2 On, Auto
Off, Output Function On and Output Function Off.
Users can extend the Auto All On, Auto Part On and
Auto Part2 On time by one hour using the Extend Auto
On Time function. Users with the appropriate assigned
authority level can change any of the eight available
skeds.
Fire Alarm Verification
You can program the D4412 Control Panel to
automatically reset smoke detectors after an alarm. If
a second alarm occurs within the verification window,
an immediate fire alarm results. This reduces potential
false alarms while providing fast response to an alarm.
Certifications and approvals
ANSI/SIA Complies with ANSI/SIA CP‑01
Control Panel Standard Features for
False Alarm Reduction
Region Certification
USA UL D4412: AMCX: Central Station Alarm
Units (UL1610, UL1635), AMTB: Con-
trol Panels, SIA False Alarm Reduction,
AOTX: Local Alarm Units (UL464,
UL609), APAW: Police Station Alarm
Units (UL365, UL464), APOU: Propriet-
ary Alarm Units (UL1076), NBSX:
Household Burglar Alarm System Units
(UL1023), UTOU: Control Units and Ac-
cessories - Household System Type
(UL985)
CSFM 7167-1615:0183 CONTROL UNIT
(HOUSEHOLD)
Installation/configuration notes
Wiring Considerations
• Up to 305 m (1,000 ft) between the control panel or
external power supply and the keypad when using
0.8 mm (#22 AWG) wire.
• Up to 610 m (2,000 ft) between the control panel or
external power supply and the keypad when using
1.2 mm (#18 AWG) wire.
• Do not exceed two keypads using 0.8 mm (#22 AWG)
wire on any 305 m (1,000 ft) run when powered from
the control panel.
• Do not exceed three keypad using 1.2 mm (#18 AWG)
wire on any 305 m (1,000 ft) run when powered from
the control panel.
Compatible Products
Keypads D297A Independent Zone Control
D621 Series LED Keypads (D621, D621W,
D621B)
D623 Series LCD Keypads (D623, D623W,
D623B)
D625 Series VF Keypads (D625, D625W, and
D625B)
Detectors D263 Series Photoelectric Smoke Detectors
D285/TH Photoelectric Smoke Detector Heads
D380 Carbon Monoxide Detector
3 | D4412 Control Panel