6 | Show the rmware version
Table 5.2: RX/TX LEDs Description
Flash pattern Function
RX (Receive) Flashing Occurs when the module
receives a message from
over-the-air.
TX (Transmit) Flashing Occurs when the module
receives a message to send
out over-the-air.
4.4 |
Conguring with USB
The B450 supports conguration by USB. Before you can access
the USB interface, you must install the RBUS1CP.inf le on the
target PC or laptop. The RBUS1CP.inf le is available on the
supplied CD-ROM.
NOTICE!
Power up the B450 with the address switch set
to the desired bus. When ready to program using
USB, turn the switch to position 0. When done
programming, turn the switch back. Failure to return
the address switch to the previous setting will result
in a trouble condition.
4.4.1 |
Install a communication program
To use USB connection from a computer to the B450 to
congure the B450, you must use a terminal emulator software
program such as Tera Term, located on the included B450 CD-
ROM.
NOTICE!
USB connection via the USB cable is only used for
temporary conguration programming.
4.4.2 |
Connect via USB cable
Insert one end of the USB cable into the PC or laptop, and insert
the other end into the B450 USB port.
4.4.3 |
Log into USB interface
Log into the USB interface and make your selections. For more
information, refer to the B450 Installation and Operation Guide.
5 |
LED descriptions
The B450 Module includes the following on-board LEDs to
assist with troubleshooting issues (refer to Figure 1.1 for the
location of the LEDs):
– Heartbeat (system status). Refer to Table 5.1.
– RX/TX communication. Refer to Table 5.2
To review the rmware version using an LED ash pattern,
tamper the B450.
Refer to Section 5 for ash patterns.
To tamper the B450, do one of the following:
– If the optional tamper switch is installed:
With the enclosure door open, close the tamper
switch.
– If the optional tamper switch is NOT installed:
Momentarily short the tamper pins (use a jumper or
screwdriver).
When the tamper switch is activated (open to closed), the
heartbeat LED stays OFF for 3 sec before indicating the
rmware version. The LED pulses the major, minor, and micro
digits of the rmware version, with a 1 sec pause after each
digit. The following is an example: The version 1.4.3 would be
shown as LED ashes:
Figure 6.1: Firmware LED ash patterns example
[3 second pause] *___****___*** [3 second pause, then
normal operation].
7 |
Certications
8 |
Specications
Dimensions
(HxWxD)
79 mm x 128 mm x 38 mm (3.11 in x 5.03 in x 1.50 in)
Voltage
(Operating)
12 VDC nominal
Current
(Maximum)
Standby: B450 with B440/B441/B442/B443 = 75mA
Alarm: B450 with B440/B441/B442/B443 = 180 mA
USB cable USB cable (Type A to A male-to-male) - not supplied It is
recommended to use Bosch cable B99 (F01U278853)
Data bus wire size 2 mm to 0.65 mm (12 AWG to 22 AWG)
Data bus wire
length
Maximum Distance
– wire size: 22 AWG (0.65 mm) --> 12 m (40 ft)
18 AWG (1.0 mm) --> 30 m (100 ft)
16 AWG (1.3 mm) --> 48 m (158 ft)
12 AWG (2.0 mm) --> 122 m (400 ft)
Using a separate UL listed power supply, such as the
B520 Auxiliary Power Supply Module, connected to the
B450 within the specication listed above, the wire
distance can be extended up to 300 m (1000 ft)
Compatibility B5512/B4512/B3512 control panel
D9412GV4/D7412GV4 (v1.00.oxx and up) control panel
D9412GV3/D7412GV3/D7212GV3 control panel
D9412GV2/D7412GV2/D7212GV2 control panel v7.06+
FPD-7024 (v1.03 and higher) control panel
AMAX 2000/2100/3000/4000 control panel
CMS 6/8/40 control panel
Solution 2000/3000
Easy Series v3+
1
B10 enclosure
1
B11 enclosure
1
D8103 enclosure
1
D203 enclosure
Relative humidity Up to 93% non-condensing
Temperature
(operating)
0° to +49° C (+32° to 120° F)
1
Temporary loss of communication may be caused by static when using any-
one of the above enclosures.
Installed Bus
Function Option/SDI SDI2 Details
IP Event Report-
ing
Y Y TCP protocols only sup-
ported on SDI2
Remote Program
(RPS or A-link)
Y Y Requires Bosch Cellular
service or other cellular
network access
Congure B450
from panel
(RPS, A-link)
N Y GV4/B Series v2.03+
Personal Noti-
cation via SMS
or Email
N Y Requires compatible con-
trol panel and cellular plan
Remote Security
Control App
N Y Requires Bosch Cellular
service or other cellular
network access
8.1 |
B450 cellular interface compatibility
Use the following table for cellular interface compatibilities.
NOTICE!
When the tamper is shorted, the rmware version
ashes, then the B450 LEDs are disabled to conserve
power. To see the troubleshooting LEDs, open the
tamper circuit or jumper.
Region Certication
US
FCC Part 15 Class B
NIST FIPS 197 AES Certication (IP Communications)
UL 365 – Police Station Connected Burglar Alarm Units and
Systems
UL 636 – Hold Up Alarm Units and Systems
UL 864 – Control Units and Accessories for Fire Alarm Systems
UL 985 – Household Fire Warning System Units
UL 1023 – Household Burglar Alarm System Units
UL 1076 – Proprietary Burglar Alarm Units and Systems
UL 1610 – Central Station Burglar Alarm Units
SIA CP-01:2010 False Alarm Reduction
California State Fire Marshall (CSFM)
Fire Department of New York (FDNY) Certied
Canada
CAN/ULC S303 - Local Burglar Alarm Units and Systems
CAN/ULC S304 - Signal Receiving Centre and Premise Alarm
Control Units
ULC - S545 - Residential Fire Warning System Control Units
ULC-ORD C1023 - Household Burglar Alarm System Units
ULC-ORD C1076 - Proprietary Burglar Alarm Units and
Systems
ICES-003 - Digital Apparatus
Europe
CE - EMC Directive 2004/108/EC
Australia
A-Tick - Certied
Flash pattern Function
Flashes once every 1 sec Normal State: Indicates
normal operation state.
3 quick ashes every 1 sec Communication Error
State: Indicates a bus
communication error with
the control panel.
On Steady Trouble State: Indicates a
trouble condition exists.
Examine the other LEDs
to determine the trouble
condition.
Off LED Trouble State: Module
is not powered, or there is a
failure in the module. Check
for proper installation.
Table 5.1: Heartbeat LED Descriptions
en Quick Start Guide
Conettix Plug-in Communicator Interface
B450