CCS 800 Ultro Discussion System | Architect and Engineering Specifications | 31
Architect and Engineering
Specifications
1. CONTROL EQUIPMENT
Control Unit with recording and digital acoustic feedback
suppression
The CU shall have a built-in recorder to digitally record a
discussion to any type of SD Card. The graphical display
shall show the status of the recorder and the accompanying
buttons shall be used to configure the recorder. As an
option, the recording shall only be active when a
microphone is active.
The SD Card shall be removable from the CU and shall be
possible to process on a PC for transcription purposes; the
recordings shall also be retrievable by connecting a PC to
the CU’s USB. The recordings shall be playable back to the
monitor loudspeaker or to delegate’s loudspeakers. An
audible beep and a flashing LED shall indicate when the SD
Card is almost full and the user needs to replace it with a
new card.
During recording it shall be possible to exchange an SD card
without the loss of any recorded audio.
The Control Unit (CU) shall have an incorporated digital
acoustic feedback suppression facility based on pre-active
algorithms (feedback is not heard). Other included features
for managing the number of active microphones and
determining the operating mode, without the need for a
central operator, should be available.
It shall be possible to connect external equipment to extend
the system capabilities. There shall be a built-in
loudspeaker and headphone connector to allow the
conference to be monitored by, for example, a
stenographer. It shall interface the following equipment to
the discussion system:
•
Tape recorder - for recording and playing back meetings
and discussions
•
External PA system - for transmitting the proceedings to
an audience in the same room or an adjacent room
•
External wired or wireless microphone - for use by guest
speakers or for audience participation. Note: The
external microphone shall be muted when the priority
button on a chairman unit is pressed, and when the
system is operating in ‘chairman only’ mode
•
Audio equipment - for providing background music
•
Telephone coupler - for allowing a remote delegate to
take part via telephone
The following five modes shall be selectable using a rotary
control on the unit’s front panel:
•
Open mode with auto-switch-off - shall allow selection
of the number of microphones, from one to four, which
can be simultaneously active. If the delegate does not
speak for 30 seconds, the microphone shall
automatically be switched off. It shall also be possible
to switch microphones off manually
•
Open mode without auto-switch-off - shall allow
selection of the number of microphones, from one to
four, which can be simultaneously active
•
Override mode - shall allow delegates to override each
other simply by activating their microphones. It shall
only be possible for one microphone to be active at any
one time. Note: In override mode, delegates shall not be
able to override chairmen
•
Chairman only mode - shall only allow chairmen to
speak. It shall not be possible to activate delegates’
microphones, even if no chairman is speaking
•
Test mode - shall be used to check that the system
connections have been made correctly. All microphone
ring and contribution unit LEDs shall light up if the unit
is properly connected
The CU shall have the following controls and indicators:
•
Mains on/off switch
•
Microphone-mode switch for selecting one of four
modes (plus test mode)
•
Rotary loudspeaker volume control for setting the
output level of loudspeakers of contribution units. This
control shall also determine the maximum level for the
headphone outputs of contribution units and CU
•
Monitoring volume control of CPSU loudspeaker or
headphones
•
‘Power on’ green LED indicator
It shall provide the following facilities:
•
Control for 150 units
•
Mains input connection
•
Two trunk outputs for loop-through connection of
contribution units. It shall be possible to connect 25
contribution units to each output. The maximum cable
length shall be not less than 100 m (109.3 yards). 150
contribution units can be connected in one system
•
Microphone input with gain adjustment for connecting
an external microphone
•
Recorder input and output with gain control
•
Line input and output for connecting a PA system or
background music source
•
Telephone coupler input and output for connecting a
telephone line. The input signal shall be isolated from
the output to prevent echoing
•
Insertion connector (with by-pass switch) for
connecting external audio processors
•
One 3.5 mm (0.1 in) stereo headphone socket
•
On/off switch for digital acoustic feedback suppression
facility
It shall be suitable for use in portable or fixed mountings. It
shall be 84 mm (3.4 in) high, 361 mm (14.2 in) wide and
143 mm (5.6 in) deep.
Control Unit with recording
This unit is identical but without digital acoustic feedback
suppression facility.
Control Unit with digital acoustic feedback suppression
This unit is identical but without recording.
Control Unit
This unit is identical but without recording and without digital
acoustic feedback suppression facility.
www.boschsecurity.com Bosch Security Systems, Inc.