Table 12 shows the available options when you install
two RS-232 modules on one system.
Table 12: Network Module Options
Available Options
Network
Module
Print Direct Connect/
Alt Comm RPS
Connection
AltComm
Reporting
Module 1 Yes Yes Yes
Module 2 Yes No Yes
If both network modules are enabled, only
the second module prints history reports.
2.1.11 RS-232 Printer Baud Rate Programming
If using the Network Communication Module to
connect the control panel to an RS-232 printer, you
can configure the module’s baud rate.
• Addresses: 4020 (Module 1); 3042 (Module 2)
• Data Digit:
• Data Digit 1: ____ (refer to Table 13;
default = 0)
• Data Digit 2: ____ (refer to Table 9;
default = 0)
• Selections: 0 to 5 for Data Digit 1
Table 13: Module 1 and 2 Baud Rate, Data Digit 1
Select Option Value
300 baud
0
1200 baud 1
2400 baud 2
4800 baud 3
9600 baud 4
14400 baud 5
2.2 Door Access Control Module
(DACM) Support
Use Keypad/DACM Assignment Programming to
assign a keypad or DACM to a keypad bus address,
and to identify its area (partition).
The DS7400XiV4 supports up to eight DACMs. Each
DACM must have a unique keypad bus address.
You can only assign a DACM to Keypad
Bus Addresses 3 to 10.
You cannot assign a DACM and a keypad
to the same address.
Once a DACM is assigned to a keypad bus address,
the control panel forces Zones 9 through 16 to the
DACM door contact zone type. If you remove all
DACMs from the system, Zones 9 through 16 return
to their programmed values. Although the zone type is
forced, the zone function programming applies. Refer
to Table 14, and also the DS7400XiV4-EXP Control
Panel Reference Guide (P/N: 4998154963).
Table 14: DACM Address, Zone, and Zone
Function Addresses
Keypad Bus
Address that
DACM Occupies
Zone Zone
Function Address
3 9 0039
4 10 0040
5 11 0041
6 12 0042
7 13 0043
8 14 0044
9 15 0045
10 16 0046
Refer to the DACM Installation Instructions
(P/N: F01U500999) for more information.
• Addresses: 3132 to 3135
• Data Digit: Refer to Table 15.
• Defaults: Refer to Table 15. If using only one
keypad, the default is an Alpha keypad belonging
to Area 1. Otherwise, the default is 0.