This chart explains the procedure for performing a Battery Test.
If a power failure occurs, your control panel has a built-in battery that will continue to power the control panel for many hours.
The control panel automatically recharges the battery when power is restored.
In addition to an automatic battery test performed every 2 minutes, the battery may also be tested manually.
This test also uses the battery to manually activate all the system sounders for 2 seconds ([PIN] [#] [8] [5] only).
If the battery voltage is low, a battery fault will occur (see
Error Displays
).
Testing your System (continued)
* = If this test is performed from a Master keypad, it must be in Single Partition Mode.
What will Happen
Command
Sequence
[PIN] + [#] [8] [5]
T
pe of
Test
Local
Batter
/
Sounder Test*
What to Do
If test fails, the control panel will indicate
a control problem. See
Error Displa
s.
If power in
our buildin
has been off
recentl
, wait 2 hours for the batter
to rechar
e and then tr
a
ain.
[PIN] + [S
stem Reset]
Batter
Test
•All ke
pad Li
hts will turn on.
•The ke
pad sounder and all alarm
soundin
devices will operate for 2
seconds.
• The control will perform a Batter
Test.
• The control will report a Low Batter
or
a Low Batter
Restoral if necessar
.