K3000 / D8300 Series
K3000 / D8300 Series KeyPAC Readers Operation & Installation Guide
17404 Ver 2.4/47556B (7/01) Page 2 © 2001 Radionics
Output format selection. Formats available are Readykey format (default), Wiegand (26 and 34bit),
Magstripe and Barcode
2.2 Specifications
K3001 Low Profile 0 in. – 4 in. (0 cm – 10 cm)
K3002 Mullion 0 in. – 3 in. (0 cm – 7.6 cm)
K3003 Vandal Resistant 0 in. – 2 in. (0 cm – 5.1 cm)
Appropriate Reading
Range for ISO Thickness
Card
These ranges will reduce if the readers are mounted on surfaces containing
metal or if they are near local sources of electrical noise.
Mullion 12 VDC (nominal), < 40 mA;
Tolerance +10.5 V to +20 V
Power Requirements
Low Profile and Vandal
Resistant
12 VDC (nominal), < 85 mA;
Tolerance +10.5 V to +20 V
Operating -31ºF to + 140ºF (-35 ºC to + 60ºC);
0-90% RH at 86ºF±5ºF (30ºC ±2ºC) for 24 hrs
Storage -31ºF to +176ºF (-35ºC to +80ºC)
Environmental
Ingress Protection Sealed to IP 66
Table 2: K3000 / D8300 Series Specifications
3.0 Installation
3.1 Unpacking
Check that all the parts are supplied with your reader. If anything is missing or damaged, contact your
suppliers immediately. The readers are each supplied with the following:
Low Profile Mullion Vandal Resistant
Two screws Two 1” screws Four Screws
Snap fit decor cover Snap fit decor cover Label
Label Label Ten cable crimps
Ten cable crimps Ten cable crimps MOV
MOV MOV
Table 3: K3000 / D8300 Series Supplied Parts
3.2 Output Format Selection
You can set the output format before installing the reader or at any point before power is connected. The
instructions given here do not contradict those in the wiring section they are only necessary for programming
the output format before the reader is wired as normal.
The default output format for this unit is Readykey. To set the reader to other output formats:
Disconnect the power before starting. Failure to do so may damage the unit.
Start with all the wires disconnected from the reader.
Output Format Brown to… Yellow to… # of Flashes on
power up
Normal power up all separate
Readykey
(default)
white - 0
Wiegand 26-bit green - 1
Wiegand 34-bit white green 2
Magstripe - green 4
Barcode green white 5
1. To select the output
format twist together
the wires as shown in
the following table:
Table 4: Output Format Selection
2. Separate the other wires and keep them separate. We suggest you use insulation tape.
3. Connect the power for 2 seconds. Connect the black wire to GND (ground) and the red to power +12 V
(10.5 V to 20 V).
Note: At this stage there will be no indication of successful format change.
4. Disconnect the power.
5. Untwist the wires and keep them separate, again we suggest you use insulation tape.