Vista de pagina 25
Plena Range | 53
www.boschsecurity.com
Communication
Technical Specifications
Electrical
Mains Voltage 230 / 115 VAC, ±10%, 50/60 Hz
Max Power Consumption 500 VA
Max Output Current 10 A
Max Mains Inrush Current 7 A @ 230 VAC / 14A @ 115 VAC
Performance
Frequency Response 60 Hz – 10 kHz
(+1/-3 dB@ -10 dB ref. rated output)
Distortion <1% @ rated output, 1 kHz
Bass Control -8/+8 dB @ 100 Hz
Treble Control -8/+8 dB @ 10 kHz
Inputs
Input 1 and 2 3-pin XLR, balanced mic/line level
(switchable)
Sensitivity 1 mV/ 1 V (mic. / line)
Impedance >1 kOhm
Dynamic Range 100 dB
S/N 75 dB (flat at max volume)
Headroom 25 dB
Phantom Power 16 V switchable
VOX Functionality Switchable input 1 mutes input 2
Sensitivity -20 dB ref nominal input
Priority Input Screw terminals
Sensitivity 100 V transformer balanced
Impedance >100 kOhm
S/N 63 dB (flat at max volume)
Headroom 25 dB
Pilot Tone Detection -20 dB ref 100 V (10 V)
Pilot Tone Threshold -26 dB ref 100 V (5 V)
Master Input 1/4" TS Jack
Only intended for slave output of another PLN-1LA10
Plugging a jack into this input disables all other inputs and the limiter.
The unit becomes a slave to the connected master. Only the master
control on the front panel will function. To monitor the level switch the
VU meter switch to “post”
Outputs
Line Output XLR balanced
Nominal Level 1V
Impedance 200 ohm
Loop Output Screw terminal
Output current 10 A
Slave Outputs 1/4”TS Jack 0° – 90°
Only intended for Master input of other PLN-1LA10
Fault Relay Screw terminals
Contacts Voltage free, max 100 V, 2 A
Environmental
Operating Temperature +5°C to +45°C
Storage Temperature -25°C to +55°C
Relative Humidity <95%
Acoustic Noise Level Of Fan <35 dB SPL @ 1m,
temperature controlled
Dimensions 94 x 430 x 320 mm
(19" wide, 2U high)
Weight approx. 11.6 kg
Rack building Mounting kit included
Controls
Supervision On/off monitor functionality and
presence of pilot tone on priority input
Metal Loss Compensation Dynamic, level dependent equalizer
Frequency Range 5 khz / 10 kHz LPF (speech/music)
Pre/Post – Master/Slave VU monitors pre limiter/AGC level or
post limiter/AGC level
Ordering Information
Model & Description
PLN-1LA10 Plena Loop Amplifier
Induction Loop Amplifier 8900 191 80001