LTC 4600 Series | Instruction Manual | Installation
Bosch Security Systems | 21 June 2004
EN
|
13
4.7 LTC 4671 Series Modules for
System4 / Allegiant Keyboard
Transmission
1. The supplied 120Ω resistor must be installed across
the external data connections when these fiber optic
modules are used with certain controller devices.
Follow the guidelines below, however, because of
differences between the hardware of new and old
controller units, these cases are not absolute. If a
configuration does not work when first connected
without using a termination resistor, try adding the
termination resistor across the data connections of
the fiber optic module located at the controller site.
A termination resistor is typically required when a
module is connected to the following controller
devices:
• Allegiant LTC 8100 Series main CPU bays
• Allegiant LTC 8200 Series main CPU bays
• Allegiant LTC 8300 Series main CPU bays
• Allegiant LTC 8900 Series main CPU bays
•LTC 8714 Series Allegiant Keyboard Expander
accessory units sold prior to 2002
•LTC 2604 Series Multiplexer Keyboard `
Expander
A termination resistor is typically NOT required when
a module is connected to the following controller
devices:
• Allegiant LTC 8500 Series main CPU bays
• Allegiant LTC 8600 Series main CPU bays
• Allegiant LTC 8800 Series main CPU bays
•LTC 8714 Series Allegiant Keyboard Expander
accessory units sold during or after 2002
If the supplied resistor is damaged or lost, any locally
obtained conventional 1/4 watt carbon resistor between
120Ω and 390Ω should suffice.
2. The POWER LED will light when AC power is
applied to the unit.
3. The DATA XTMR LED will flash as the external
data received by the unit is being optically
transmitted.
4. The DATA REC LED will flash as optical data is
being received by the unit.