Bosch LTC 8714 Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
3
LTC 8568/00 Signal Distribution Unit
Main site biphase control code distribution and line driver
unit for communicating to receiver/drivers, switcher/
followers, and satellite systems. Provides 32 separate
outputs for driving up to 256 remote devices. Either "star"
or "daisy chain" wiring configurations may be used. Two
meter (6 ft) interface cable for data/power between unit
and main CPU bay supplied. Not applicable to the
LTC 8100, LTC 8200, & LTC 8300 Series systems.
Electrical
Operating Voltage: 12 VAC (supplied by main CPU bay).
Power: 3 W.
Indicators:
Power: LED.
Code: LED.
Connectors:
Input: 9-pin connector for data/power.
Outputs: Sixteen 6 contact removable screw terminal blocks
for code output. Maximum transmission distance is
1.5 km (5000 ft) using 1 mm
2
(18 AWG) shielded-
twisted pair (Belden 8760 or equivalent).
Mechanical
Construction/Finish: Charcoal colored metal enclosure.
Dimensions: 445 W x 318 D x 89 H mm (17.5 x 12.5 x
3.5 in). Integral mounting flanges for EIA 19-inch rack.
Weight: 1.8 kg (4 lb).
LTC 8768/00 Signal Distribution Unit
Same features and specifications as the LTC 8568/00 except
that it contains twice the number of output connectors
which provide 64 separate outputs for driving up to 512
remote devices. Not applicable to the LTC 8100, LTC 8200,
& LTC 8300 Series systems.
LTC 8540/00 Alarm Interface Unit
Unit accepts up to 64 contact closures or logic level inputs
from remote sensing devices such as door contacts, PIRs,
etc. and then reports the "alarm" information to the main
CPU bay. Alarm inputs may be configured in groups of 32
to accept either normally open or normally closed contacts.
Unit also contains eight relay outputs which operate upon
alarm conditions. A two meter (6 ft) interface cable for
data/power between unit and main CPU bay is supplied.
Not applicable to the LTC 8100, LTC 8200, & LTC 8300
Series systems.
Electrical
Operating Voltage: 12 VAC or 12 VDC (12 VAC is
supplied by main CPU bay).
Power: 8 W.
Indicators:
Power: LED.
Alarm: LED, audible tone.
Connectors:
Alarm Inputs: 64; twenty 6-contact removable screw
terminal blocks for alarm inputs.
Alarm Outputs: Four 6-contact removable screw terminal
block; relay outputs (100 VDC, 0.5 A, 10 W).
Data/Power: One 9-pin connector.
Mechanical
Construction/Finish: Charcoal colored metal enclosure.
Dimensions: 445 W x 318 D x 89 H mm (17.5 x 12.5 x
3.5 in). Integral mounting flanges for EIA 19-inch rack.
Weight: 1.8 kg (4 lb).
LTC 8560 Series, LTC 8561 Series,
LTC 8562 Series, LTC 8563/20,
LTC 8564/20, LTC 8566 Series
Receiver/Drivers
On-site receiver/drivers for control of pan/tilt, zoom lenses,
auxiliary functions, etc. Refer to separate data sheets for
complete specifications.
G3 AutoDome Series
The G3 AutoDome system integrates high speed panning
and tilting, 360° continuous rotation, pre-positions, etc. in a
small, easy-to-install lightweight package. Refer to separate
datasheet for complete specification.
LTC 8569, LTC 8570, LTC 8571, LTC 8572
Series Code Merger Units
Control code merger and line driver units used to combine
Allegiant biphase control code from two (up to four with
LTC 8570 and LTC 8572 versions) systems for
communicating to receiver/drivers, switcher/followers, and
Satellite systems. The LTC 8569, LTC 8570 Series provides
32 separate outputs capable of driving up to 256 remote
devices. The LTC 8571, LTC 8572 Series provides 64
separate outputs capable of driving up to 512 remote
devices. Either "star" or "daisy chain" wiring configurations
may be used. Two (four with LTC 8570 and LTC 8572) data
cables for interface to Allegiant main CPU bays supplied.
Unit will accept signal input either from Allegiant main CPU
bay, LTC 8568/00 output, LTC 8780 biphase output, or an
output from another LTC 8569, LTC 8570 Series or
LTC 8571, LTC 8572 Series unit. Multiple units may be
cascaded to obtain additional outputs.
Electrical
Model Rated Voltage Power
No. Voltage Range
LTC 8569/60, LTC 8570/60 120 VAC, 50/60 Hz 108 to 132 12 W
LTC 8571/60, LTC 8572/60
LTC 8569/50, LTC 8570/50 230 VAC, 50/60 Hz 198 to 264 12 W
LTC 8571/50, LTC 8572/50
Indicators:
Power: LED.
Code: LED.
Connectors:
Inputs:Two 9-pin connectors (four with LTC 8570 Series
and LTC 8572 Series).
Outputs: Sixteen (32 on LTC 8572 Series) 6 contact
removable screw terminal blocks for code output.
Maximum transmission distance is 1.5 km (5000 ft) using
1 mm
2
(18 AWG) shielded-twisted pair (Belden 8760 or
equivalent).
AC Input: 3-wire power cord with grounded plug; 1.8 m
(6 ft) long.
Mechanical
Construction/Finish: Charcoal colored metal enclosure.
Dimensions: 445 W x 318 D x 89 H mm (17.5 x 12.5 x
3.5 in). Integral mounting flanges for EIA 19-inch rack.
Weight: 5.3 kg (11.7 lb).
Vista de pagina 2
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios