• Remote Programming Software (RPS) Lite allows end
users to perform control panel management tasks –
Add/Delete/Change user passcodes and authorities,
view and print the panel history event log
• Custom keypad text is fully programmable, including
remote programming
• Full function command menu including Custom
Functions
• Authority by area and 16‑character name for each
user
• 14 custom authority levels control user’s authority to
change, add, or delete passcodes or access control
credentials; to disarm or bypass points; and to start
system tests
Area Configurations
Area programming offers a wide selection of different
system configurations. Each area is assigned an
account number to define annunciation, control, and
reporting functions. Multiple areas can be linked to a
shared area which is automatically controlled (hallway
or lobby). Area arming can be conditional on other
areas (master or associate). Any area can be
configured for perimeter and interior arming, not
requiring a separate area for this function.
Custom Functions
For added convenience, Custom Functions can be
programmed to eliminate keystrokes for users allowing
the installer to program an easy command for a
complicate function. For example, a custom function
can be written to bypass a group of points and arm
the system, allowing the user to perform this function
with one easy command. This can be used to control a
particular room, or even a single door allowing
customized access. In additions, Custom Functions
can be activated with a token or card, or automatically
as a scheduled event (SKED) providing further
flexibility and ease of use.
Door‑Activated Custom Function
A custom function activates when user credentials are
presented to a D9210C Access Control Interface
Module door controller's reader. The custom function
behaves as though the user performed a function at
the keypad associated with the door controller.
Passcode Security
For high security applications, GV4 can be configured
for several different passcode options.
• Dual Authentication – requires a user to enter their
passcode and also use a token or card.
• Two-Man Rule - Requires two people with two unique
passcodes to be present at the time of opening.
• Early Ambush - Allows users to verify that the facility
is safe by requiring two passcode entries at different
keypads within the same area, sending a duress event
if the user does not enter the passcode a second time
after inspecting the premises.
Easy Exit Control
The D9412GV4 Control Panel changes from one armed
state to another armed state without disarming. For
example, if you change the state from Perimeter Arm
to Master Arm, the control panel complies and reports
the change. Easy Exit Control reduces the number of
keystrokes, simplifying system operation.
Programmable Passcode‑controlled Menu List
The system prompts users to enter a passcode prior to
viewing the keypad menu. The keypad display shows
the user the menu options allowed according to the
user’s authority level. Passcode-controlled menus
provide users only with the options and information
pertinent to them, simplifying system operation.
Flexible Control
The system provides the flexibility to select added
convenience or high security. For example, you can
restrict passcode arming and disarming to a keypad's
immediate local area, even if the user has access to
other areas. This is particularly useful for high security
areas, where a user may have access to the area, but
would prefer to only disarm the area individually rather
than with the rest of the system. Another option is to
program the system to disarm all areas the user can
access from any keypad.
Invisible Walk Test
A menu item allows the user to test invisible 24‑hour
points within the scope of the keypad without sending
a report to the central station.
System Users
The system supports up to 1000 users, each can have
a passcode, an access token and a wireless keyfob.
User passcodes contain three to six digits. Passcodes
can be assigned to one of 14 customized authority
levels in each area, and can be restricted to operate
only during certain times.
Communication Formats
The D9412GV4 Control Panel prioritizes and sends
reports in Contact ID or Modem IIIa
2
communications
formats to four route groups. Each group has a
programmable primary and backup destination.
The D9412GV4 provides flexible communications for
most central stations with reporting capabilities such
as:
• Individual point numbers
• Opening or closing reports by user and area number
• Remote programming attempts
• Diagnostic reports
IP Communication
The D9412GV4 uses the B426/B420 Connetix Ethernet
Communication Module, DX4020 and/or the
ITS‑DX4020‑G Cellular Communicator to communicate
with the Conettix D6600 and D6100i Communications
Receiver/Gateways. Using Conettix IP communication
offers a secure path that includes anti-replay/anti-
2
| D9412GV4 Series Control Panels
Comentarios a estos manuales