5 Specification
Panel
Enclosure :
Dimensions (HxWxD): 260mm x 280mm x 83,5mm
Weight: – 1950g
Environmental Considerations:
Relative Humidity: 10%-95%
Operating Temperature: -10°C - +55°C
Supervised Zones:
Onboard:
Z1 - Z8 COM 8 Single or dual end-of-line (EOL 2,2KΩ) tamper point
support
P8 Tamper Enclosure tamper input (does not reduce point capacity)
Programmable Outputs (PO):
Onboard:
OC 1 supervised output max 500mA
OC 2 supervised output max 500mA
P7 Relay output max 100mA
Auxiliary module
(DX3010):
Relay 1-8 Contacts rated 5A at 28VDC
Cable requirements: Unshielded and shielded 0,6-0,8mm
Number of...
Users: 16 (8 + 8Keyfob)
Key Fobs: 8
Events: 254 history events, stamped with time and date
254 EN history events, stamped with time and date
Pin Code variations 10000
DX 3010: 1
B 420 or DX 4020 or DX
40206
–1
Keypads: 2
Power:
Power Supply Type: A
Transformer: 230V Input/18VAC 20VA Fuse=500mA
AC Input: AC Input Voltage: 195 VAC to 253 VAC
Line Voltage Frequency: 50 Hz
DC Output: maximum current for all components 1100mA
maximum current for all components 550mA (recharge Batt
80% in 72h)
Aux (+12V/GND) Output: Nominal Output Voltage under AC line input: 13,5 VDC +3%
/ -5%