AMAX panel 2000 / AMAX panel 2000 EN Specification | en 25
Robert Bosch Engineering and Business Solutions LimitedQuick Reference Guide F.01U.241.128 | V2 | 2011.11
– Output Voltage Range under AC line input: 12,82 VDC to
13,9 VDC
– 500mA maximum
– Vpp (max) 675mV
Option Bus: – Nominal Output Voltage under AC line input: 13,5 VDC +3%
/ -5%
– Output Voltage Range under AC line input: 12,82 VDC to
13,9 VDC
– 500mA maximum
RF Power Output – 5VDC / 100mA maximum
Panel PCB – Quiescent current maximum 100mA
Battery: – D126 (12V/7 Ah) sealed, lead acid rechargeable
– Low battery condition is below 11,8 VDC
– Minimum battery condition is 10,8VDC
– Maximum auxiliary current to recharge standby battery to
80% within 72h:
– 12 V/7 Ah Battery: 550 mA
Certification: – EN 50131-3 Grade-2 Env-II
Keypads:
IUI-AMAX-LED8 (8Zone LED Keypad)
Relative Humidity: – 10%-95%
Operating Temperature: – -10°C - +55°C
Input Voltage range: – 10VDC - 14VDC
Current Consumption – standby 24mA
– maximum 50mA
Cable requirements: – four wire, unshielded and shielded 0,6-0,8mm
– maximum length 150m
EN type: – B
IUI-AMAX-LCD8 (8Zone LCD Keypad)
Relative Humidity: – 10%-95%
Operating Temperature: – -10°C - +55°C
Input Voltage range: – 10VDC - 14VDC
Current Consumption – standby 18mA
– maximum 60mA
Cable requirements: – four wire, unshielded and shielded 0,6-0,8mm
– maximum length 150m
EN type: – B