Bosch Security Systems | 2003-06 | 3922 988 54284
CCS 800 Ultro | Installation and Operating Manual en | 22
9.1.5 Headphone Jack-plug (3.5mm) (E)
1 Tip - Signal +
2 Ring - Signal -
3 Sleeve - Electrical earth/screen
9.1.6 Mounting of connectors,
LBB 3316/00
Figure 9.2
9.2 Mounting Instructions
The CPSU can be attached in three different ways:
In a 19" rack making use of the 19" rack mounting
set LBB 3311/00. Place a blank 1HU panel above the
CPSU to have sufficient space for cable connections.
Mounted into a table using the flush mount bracket.
On a table. Therefore drill four holes in the table and
fasten the CPSU with four M3 screws (B).
The delegate and chairman units can only be attached
on a table. Therefore drill two holes in the table and
fasten the unit with two M3 screws (A).
Figure 9.3
1
6
4
2
5
3
7
31
6
5
2
4
7
Yellow
Drain
Shield
Shield
Green
Violet
Blue
Red
White
C
C
S
8
0
0 U
L
TR
O
Figure 9.4
34
AB
Ø3.5 (2x)
(4x)
342.5
+0.5
0
4
95.8
Vista de pagina 19