Intrusion Systems | D9412GV2 Control Panel
The D9412GV2 Control Panel provides an integrated
solution for intrusion, access control, and fire alarm
system applications. Monitor alarm points for intruder
or fire alarms while operating user keypads and other
outputs. The D9412GV2 Control Panel includes a
communicator that sends events to selected public
switched telephone network (PSTN) or IP network
destinations through four programmable route groups.
Program all system functions on-site through a D5200
Programmer or remotely through Remote Programming
Software (RPS).
Add up to eight doors of access control using the
optional D9210BLC Access Control Interface Module.
The D9412GV2Control Panel provides up to 246
individually identified points. Each point accommodates
normally-open (NO) and normally-closed (NC) devices
with end-of-line (EOL) resistor supervision. Program
points for fire, fire supervisory, or intrusion applications.
Functions
Programmable Outputs
2 A alarm power at 12 VDC
1.4 A auxiliary power at 12 VDC
Four alarm output patterns
Programmable bell test
Programmable bell shut-off timer
System Response
31 custom point indexes, including fire supervisory
Selectable point response time
Cross point capability
Fire alarm verification
Fire inspector’s local test
Watch mode
Scheduled events (skeds) arm, disarm, bypass and
unbypass points, control relays, control authority
levels, and control door access
User Interface
Supervises up to eight command centers (up to 32 un-
supervised keypads can be used)
Custom keypad text
Full function command menu including custom
functions
Each user has authority by area and 16-character
name
14 custom authority levels control user’s authority to
change, add, delete passcodes or access control
credentials, disarm, bypass points, and start system
tests
Note
Use at least one keypad in each system.
D9412GV2 Control Panel
Fully integrated intrusion, fire, and access control
allows users to interface with one system instead of
three
NetCom IP based communication option provides
high-speed, secure alarm transport and control
Eight programmable areas with perimeter and interior
partitioning
246 points with flexible configuration options to meet
multiple installation requirements
Your choice of vacuum fluorescent or ATM style user
interface keypads
New user interface functions provide additional
security and flexibility
Up to 238 RF points
www.boschsecurity.com
Vista de pagina 0
1 2 3 4 5 6

Indice de contenidos

Pagina 1 - D9412GV2 Control Panel

Intrusion Systems | D9412GV2 Control PanelThe D9412GV2 Control Panel provides an integratedsolution for intrusion, access control, and fire alarmsyste

Pagina 2 - 2

2 | D9412GV2 Control PanelArea ConfigurationsArea programming offers a wide selection of differentsystem configurations. Assign an account number toe

Pagina 3 - D9412GV2 Control Panel

D9412GV2 Control Panel | 3threshold of stored events, it can send an optionalreport to a receiver.Access ControlThe D9412GV2 provides custom door stri

Pagina 4 - 4

4 | D9412GV2 Control PanelD127 Reversing Relay ModuleD129 Class A Initiating ModuleD130 Auxiliary Relay ModuleD185 Reverse Polarity Signaling ModuleD

Pagina 5 - D9412GV2 Control Panel

D9412GV2 Control Panel | 5Technical SpecificationsCommunicationsSDI Bus A (+): 9 VDC4572 m (15,000 ft)SDI Bus B (-): 9 VDC4572 m (15,000 ft)Telephone

Pagina 6 - 6

6 | D9412GV2 Control PanelOrdering InformationD928 Dual Phone Line SwitcherAllows the control panel to operate over and supervise two separate phonel