User Interface
Supervises up to eight command centers (up to 32
non-supervised command centers can be used)
Custom command center text
Four custom functions
Full function command menu including custom
functions
Each user has authority by area and 16-character
name
14 custom authority levels control user’s authority to
change, add, delete passcodes, delete access control
tokens, delete cards, disarm, bypass points, and
initiate system tests
Up to 40 programmable, scheduled events and up to
16 event functions for controlling relays, enabling
passcodes and windows, and automatically arming
and disarming areas
Adjustable brightness or volume for command center
display or sounder
One parallel printer
The D7212GV2 provides on-premises point and system
status annunciation. The fully selectable user interface
customizes command center displays and allows users
to create appropriate menu items and functions.
Function lists can help a user become familiar with the
operation of the control panel and custom functions
allow users to perform complex functions with a few
keystrokes. Each function can be programmed and
identified by sixteen characters of custom text and can
contain up to 32 keystrokes.
Notice
At least one command center per system is
recommended.
Two Man Rule
Two Man Rule requires two unique passcodes on the
same command center to disarm an area. Without the
second passcode, the system denies entry. Two Man
Rule requires the presence of two people at opening,
providing added security.
Early Ambush
Early Ambush requires two passcode entries on the
same command center. Enter the same passcode
twice or have two unique passcodes, depending on
the configuration. The first entry disarms the area and
the second entry stops a timer programmed to send a
duress event. If the second entry does not occur
within the programmed time, the system generates a
duress event. Early Ambush allows users to inspect the
premises and use the system to confirm that the area
is safe to enter, providing added security.
Easy Exit Control
The D7212GV2 Control Panel changes from one armed
state to another armed state without disarming. For
example, if you change the state from Master Arm to
Perimeter Arm, the control panel complies and reports
the change. Easy Exit Control reduces the number of
keystrokes, simplifying system operation.
Programmable Passcode-controlled Menu List
The system prompts users to enter a passcode prior to
viewing the command center menu. The command
center display shows the user the menu options
allowed according to the user’s authority level.
Passcode-controlled menus provide users only with
the options and information pertinent to them,
simplifying system operation.
Passcode Follows Scope
Use Passcode Follows Scope to restrict passcode
arming and disarming only to the command center's
immediate local area, even if the command center can
report events from other areas. Passcode follows
scope simplifies the arming and disarming procedure
without limiting any other command center command
capabilities.
Passcodes
User passcodes contain three to six digits. Assign each
user one of 14 customized authority levels in each
area. Restrict passcodes to operate only during certain
times.
The Two Man Rule and Early Ambush options require
two passcodes, providing additional security in
financial establishments such as banks.
Communications
The D7212GV2 prioritizes and sends reports to four
route groups. Each group has a programmable primary
and backup destination.
The D7212GV2 works with the D6600 NetCom
Communications System using a DX4020 Network
Interface Module. It has programmable anti-replay anti-
substitution features when using a DX4020.
The Modem IIIa
2
Communications Format, available
with Bosch receivers, adds reporting capabilities such
as:
Individual point numbers and text
Opening or closing reports by area number
Remote programming attempts
Diagnostic reports
Security and Fire Detection
The D7212GV2 Control Panel provides eight on-board
points, and up to 32 additional off-board points
(depending on model and expansion interfaces). You
can program individual points to monitor all types of
burglar alarms, fire alarms, and supervision devices.
Event Log
The event log stores up to 1,000 local and transmitted
events. The event log includes time, date, event, area,
point, and user number. View the event log from select
command centers or remotely retrieve event
information using RPS. RPS operators can retrieve
events periodically using one phone call, rather than
receiving several calls each day. When the event log
reaches a programmed threshold of stored events, it
can send an optional report to a receiver.
2
| D7212GV2 Control Panel