D9412GV2 Control Panel | 5
Technical Specifications
Communications
SDI Bus A (+): 9 VDC
4572 m (15,000 ft)
SDI Bus B (-): 9 VDC
4572 m (15,000 ft)
Telephone Connec-
tion:
•
One telephone line
•
D928 Dual Phone Line Module required for two tele-
phone lines
Environmental Considerations
Relative Humidity: 5% to 93% at +30°C (+86°F), non-con-
densing
Temperature (Operating): 0°C to +50°C (+32°F to +120°F)
Number of…
Areas: 8
Card Readers (Doors): 8
Credentials (Tokens): 996
Custom Functions: 16
Events: Up to 1000
Passcode Users: 249, plus 1 service passcode
Parallel Printers: 3
Points: 246 (8 on-board, up to 238
off-board)
Programmable Relay Outputs: 131
RF Points: 238
SKEDs: 64
Power Requirements
Current Draw (Maximum): 300 mA
Output (Alarm): 2 A at 12 VDC
Output (Auxiliary, Continuous Power,
and Switched Auxiliary combined):
1.4 A at 12 VDC nominal
Voltage (Operating): 12 VDC nominal
Voltage (AC): 16.5 VAC 40 VA plug-in transformer
(D1640)
Ordering Information
D9412GV2 Control Panel
Includes one printed circuit board (PCB).
D9412GV2
D9412GV2 Attack-Resistant Kit
Contains one PCB, one transformer, and one at-
tack-resistant enclosure.
D9412GV2-A
D9412GV2 Fire and Burglar Kit
Contains one PCB, one dual battery harness, two
telephone cords, one telephone line switcher,
one transformer, and one fire enclosure.
D9412GV2-B
D9412GV2 Commercial Burglar Kit
Contains one PCB, one lock and key set, one
transformer, and one universal enclosure.
D9412GV2-C
Hardware Accessories
D110 Tamper Switch
Screw-on tamper switch that fits all enclosures.
Shipped in packages of two.
D110
ICP-EZTS Dual Tamper Switch
Combination tamper switch with a wire loop for
additional tamper outputs.
ICP-EZTS
Ordering Information
D101 Lock and Key Set
Standard lock set with one key supplied. Uses the
D102 (1358) replacement key.
D101
D122 Dual Battery Harness
Harness with circuit breaker. Connects two bat-
teries to a compatible control panel.
D122
D122L Dual Battery Harness with Long Leads
Color-coded harness with circuit breaker and
leads measuring 89 cm (35 in.). Connects 12 V
batteries to compatible control panels.
D122L
D137 Mounting Bracket
Used to mount accessory modules in D8103,
D8108A, and D8109 enclosures.
D137
D138 Mounting Bracket, Right Angle
Used to mount accessory modules in D8103,
D8108A, and D8109 enclosures.
D138
D168A Remote Telephone Cord
A remote control module that arms or disarms a
security system remotely or locally through a tele-
phone.
D168A
www.boschsecurity.com