Bosch DS7400XiV4-EXP Guía de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
DS7400XiV4-EXP | Wireless Reference Guide | 3.0 Adding Wireless Sensors/Contacts EN | 8
Bosch Security Systems | 6/05 | 4998154962B
Table 4: Zone Function Programming (Address 0001 to 0030, Data Digit 1)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Invisible Alarm
Silent Alarm
Steady Alarm Output
Pulsing Alarm Output
Alarm on Short
Alarm on Open
Trouble on Open
1
Trouble on Short
1
Only when disarmed. When armed, this becomes Alarm on Open or Short for non-24-hour zones.
NOTE: Multiplex contacts should not be programmed for Trouble on Open.
Table 5: Zone Function Programming (Address 0001 to 0030, Data Digit 2)
Select Options Value Select Options Value
Interior Delayed 0 Day Monitor 8
Perimeter Instant 1
Keyswitch
2
9
24-Hour 2 Fire Zone with Verification *0
Entry/Exit Delay #1 3 Fire Zone without Verification *1
Entry/Exit Delay #2 4 Waterflow *2
Interior Entry/Exit Follower 5 Supervisory *3
Interior Home/Away 6 Entry/Exit Delay Cancel 1 *4
Interior Instant 7 Entry/Exit Delay Cancel 2 *5
2
If Data Digit 2 = 9 (keyswitch), refer to Table 6 to determine the value for Data Digit 1.
Table 6: Address 0001 to 0030, Data Digit 1, if
Data Digit 2 = 9
Select Options Value
Single Partition – No Force Arm 0
Single Partition – Can Force Arm 1
All Partitions – No Force Arm 2
All Partitions – Can Force Arm 3