BL20
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
The BL20 Solution
The BL20 modular concept is a very flexible approach to terminal-wired I/O. The gateway, base and electronic
modules provide many benefits to the user.
• The gateway provides communication between the fieldbus and I/O modules; modules are not dependent on the
fieldbus protocol.
• DIN-rail mountable base modules are available with different wiring configurations to suit the user’s needs.
• Electronic modules are hot swappable.
• Power distribution modules can be used to create isolated power segments within the system.
BL20’s openness and flexibility provide a viable alternative to traditional PLC I/O.
Maximum Size of a BL20 Station
BL20 stations consist of a gateway and a maximum of 74 I/O modules (equivalent to 1 m station length). Some high-tech
and analog I/O modules may consume or produce large amounts of data, and therefore may further limit the number of
modules that may be used. It is highly recommended that I/Oassistant software is used when planning and commissioning
BL20 systems. This program allows you to build the BL20 node on your computer and verify that all restrictions with
regard to power and size are met. The free I/Oassistant software is available to download from TURCK website.
Addressing
BL20 Power Distribution
The power supply for a BL20 station is fed via power feeding or bus refreshing modules; the latter also being responsible for
the power supply to the internal module bus. Bus refreshing modules are used within a BL20 station (without gateway
supply) if the system supply to the BL20 modules (nominal current IMB 1.5 A) is no longer sufficiently guaranteed. Bus
refreshing modules are used with tension clamp (BL20-P3T-SBB-B or BL20-P4T-SBBC-B) or screw connection base
modules (BL20-P3S-SBB-B or BL20-P4S-SBBC-B). Power feeding modules are used if the system supply to the BL20
modules (nominal current IL < 10 A) is no longer sufficiently guaranteed.
System Supply Via Module Bus
The amount of BL20 modules that may be supplied by a bus refreshing module via the internal module bus depends on the
respective minimal current IMB of the individual modules on the bus. The sum of the nominal current inputs of the
connected BL20 modules must not exceed 1.5 A. BL20 gateway power requirements (supplied by the first bus refreshing
module) should be considered when calculating the required number of bus refreshing modules. If I/Oassistant software is
used, an error message is generated automatically via the <Station - Verify> as soon as the system supply is no longer
sufficiently guaranteed.
All bus refreshing modules used in a BL20 station should be connected via the same frame potential. The power supply to
the bus is fed via the connections 11 (plus) and 21 (ground) of the respective base module for the bus refreshing module.
Vista de pagina 0
1 2 3 4 5 6 ... 59 60

Indice de contenidos

Pagina 1 - System Supply Via Module Bus

BL20Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] BL20 SolutionThe BL20 modular concept is a very flexible

Pagina 2 - Access to the C-rail

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-2DI-24VDC-P withBL20-S3*-SBB**2 B20-3A PNP 1B

Pagina 3 - Environmental Conditions

BL20-E-8DI-24VDC-PBL20-E-16DI-24VDC-P16DI..Discrete Input EconomyModule•Modular I/O• Fieldbus Independent Configuration•IP 20 Protection•Base and Elec

Pagina 4

BL20Part NumberCountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-E-8DI-24VDC-P8 B20-E1 PNP 1BL20-E-16DI-24VDC-P16 B2

Pagina 5

BL20-4DI-NAMURNAMUR Input Module•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•NAMUR InputsElectrical• Operating Current: <40 mA

Pagina 6

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-4DI-NAMUR withBL20-S4*-SBBS**4 B20-4C NAMUR X

Pagina 7

BL20-2DO-24VDC-2A-PBL20-2DO-24VDC-0.5A-NBL20-2DO-24VDC-0.5A-PBL20-4DO-24VDC-0.5A-PDiscrete DC OutputModules•Modular I/O•Fieldbus Independent Configura

Pagina 8

BL20Part NumberInput CountPinoutCurrentIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-2DO-24VDC-0.5A-P with BL20-S3*-SBC**4 B20-3B 0.5 A 1BL20-2D

Pagina 9

BL20-E-8DO-24VDC-0.5A-PBL20-E-16DO-24VDC-0.5A-PDiscrete Output EconomyModule•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Base and

Pagina 10 - Input Connectors

BL20Part NumberInput CountPinoutCurrentIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-E-8DO-24VDC-0.5A-P8 BO-E1 0.5 A X 1BL20-E-16DO-24VDC-0.5A-P

Pagina 11

BL20-2DO-R-COBL20-2DO-R-NOBL20-2DO-R-NCDiscrete relay OutputModules•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Relay OutputsElect

Pagina 12

Creating Potential GroupsBoth bus refreshing modules and power feeding modules may be used to create a potential group. The base modulecreates the po

Pagina 13

BL20Outputs DataOutByte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0n–1 (Data for modules to the left)n Data for next discrete modules O-1 O-0n+1 (

Pagina 14

BL20-2DI-120/230VAC-PDiscrete AC Input ModuleElectrical• Operating Current: <28 mA (from VMB)<20 mA (from VIO)Power Distribution• Inputs: VIO•

Pagina 15

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-2DI-120/230VAC-P withBL20-S3*-SBB**2 B20-3C A

Pagina 16 - B20-6BB20-3B

BL20-2DO-120/230VAC-0.5ADiscrete AC Output Module•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•AC OutputsElectrical• Operating Curr

Pagina 17

BL20Part NumberOutputCountPinoutCurrentIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-2DO-120/230VAC-0.5A-P withBL20-S3*-SBC**2 B20-3B 0.5 A 1* T

Pagina 18

BL20-32DI-24VDC-PBL20-16DI-24VDC-PDiscrete Input Blocks•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesElectrical•

Pagina 19

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-16DI-24VDC-P withBL20-B3*-SBB**16 B20-B3A PNP

Pagina 20

BL20-32DO-24VDC-0.5A-PBL20-16DO-24VDC-0.5A-PDiscrete Output Blocks•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesE

Pagina 21

BL20Part NumberOutputCountPinoutCurrentIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-16DO-24VDC-0.5A-P withBL20-B3*-SBC**16 B20-B3B 0.5 A 1BL20-

Pagina 22

BL20-2AI-U(-10/0 to +10VDC)BL20-2AI-I(0/4 to 20MA)BL20-1AI-U(-10/0 to +10VDC)BL20-1AI-I(0/4 to 20MA)Analog Input Modules•Modular I/O•Fieldbus Independ

Pagina 23

BL20General Technical DataPotential isolations Via OptocouplerAmbient temperatureOperating temperature +32 to +131°F (0 to +55°C)Storage temperature -

Pagina 24

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-1AI-U(-10/0 to +10VDC) withBL20-S4*-SBBS**1 B

Pagina 25

BL20-4AI-U/IAnalog Input Module•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Voltage and Current InputsElectrical• Operating Curren

Pagina 26

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-4AI-U/I withBL20-S6*-SBCSBC**4 B20-6C0/4 to 2

Pagina 27

BL20-2AI-THERMO-PIBL20-2AI-PT/NI-2/3Temperature Input Modules•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Thermocouple or RTD Inpu

Pagina 28 - B20-B6B B20-B3B

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-2AI-PT/NI-2/3 withBL20-S4*-SBBS**2 B20-4F RTD

Pagina 29

BL20-2AO-I(0/4 to 20MA)BL20-2AO-U(-10/0 to +10VDC)BL20-1AO-I(0/4 to 20MA)Analog Output Modules•Modular I/O•Fieldbus Independent Configuration•IP 20 Pr

Pagina 30 - B20-4D B20-4E

BL20Part NumberOutputCountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-1AO-I(0/4 to 20MA) withBL20-S3*-SBB**1 B20-3D

Pagina 31

BL20-1RS232BL20-1SSIBL20-1RS485/422Serial I/O Modules•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesElectrical• Op

Pagina 32

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionOutputCountPinoutStyleIndividualDiagnosticsWire-BreakDete

Pagina 33

BL20-1CNT-24VDCCounter Module•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Counter InputElectrical• Operating Current: <50 mA (f

Pagina 34 - B20-4G B20-4F

BL20-GWBR-DNETDeviceNet Gateway•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesElectrical• Operating Current: <2

Pagina 35

BL20Part NumberInput CountPinoutStyleGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-1CNT-24VDC withBL20-S4*-SBBS**1 B20-4K Counte

Pagina 36 - B20-3D B20-3E

BL20-PF-120/230VAC-DBL20-PF-24VDC-DPower Feeding Modules•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Supply AC or DC I/O PowerElec

Pagina 37

BL20B20-P3Part Number PinoutBL20-PF-120/230VAC-D with BL20-P3*-SBB**B20-P3BL20-PF-120/230VAC-D with BL20-P4*-SBBC**B20-P4BL20-PF-24VDC-D with BL20-P3*

Pagina 38 - Input/Output Connectors

BL20-BR-24VDC-DBus Refreshing Module•Modular I/O•Fieldbus Independent Configuration•IP 20 ProtectionElectrical• Module Bus Supply: <1.5 A• I/O Sup

Pagina 39

BL20B20-P3A B20-P4APart Number PinoutBL20-BR-24VDC-D with BL20-P3*-SBB-B**B20-P3ABL20-BR-24VDC-D with BL20-P4*-SBBC-B**B20-P4A* T = Tension clampS = S

Pagina 40

Each gateway can support up to 3 SWIRE modules for a total of 48 non-reversing motor starters on a single gateway. Anyreversing motor starter is consi

Pagina 41

BL20Available Motor Starter SizesPart NumberMotor Rating @ 480 VACRated OperationalCurrent @ 480 VACRated UninterruptedCurrent @ 480 VACClassification

Pagina 42

hp Motor Contactor Part NumberWiring Set PartNumberRelay Part NumberSWIRECommunication0.08 PKZM0-0.25PKZM0-XDM12DILM7-10(24 VDC)BL20-SWIRE-DIL0.12 PKZ

Pagina 43

BL20Reversing Part Numbershp Part NumberWiring SetNumberRelay Part Number Relay Part NumberSWIRECommunicationSWIRECommunicationMechanicalInterlock0.08

Pagina 44 - B20-P3A B20-P4A

•Modular Motor Starter Control•Fieldbus IndependantConfiguration•IP 20 Protection•Base and Electronics in One PartSWIRE EconomyCommunication ModuleBL2

Pagina 45 - BL20 Motor Starter Modules

BL20BL20-GW-DPV1PROFIBUS-DP Gateway•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesElectrical• Operating Current: &

Pagina 46 - Available Motor Starter Sizes

BL20Part NumberInput CountPinoutCurrentGroupDiagnosticsIndividualDiagnosticsWire-BreakDetectionI/O MapBL20-E-1SWIRE13 AX X 1Note: This module can onl

Pagina 47 - Non-Reversing Part Numbers

• Wires Motor Overload Contactor to Relay ModuleMotor Starter Wiring SetHousing Part Number ApplicationPKZM0-X*M*2•Different styles for different ampe

Pagina 48 - Reversing Part Numbers

BL20• Controls SWIRE Communication and Activates the Motor StarterSWIRE CommunicationHousing Part Number ApplicationBL20-SWIRE-DIL•Use with all DILM*

Pagina 49

Power Feed Module• Safety Zone SeparationHousing Part Number ApplicationBL20-SWIRE-PF•Separate motor starter sets into separate safety zones• Easily C

Pagina 50

BL20Base Modules for Slice I/OHousing Part Number DescriptionThree Terminal Block BL20-S3T-SBBTension Clamp ConnectionBL20-S3S-SBBScrew Terminal Conne

Pagina 51 - Motor Overload Contactor

Base Modules for Slice I/OHousing Part Number DescriptionFour Terminals with C-Connection BL20-S4T-SBBCTension Clamp ConnectionBL20-S4S-SBBCScrew Term

Pagina 52 - Relay Module

BL20Housing Part Number DescriptionThree Terminal Block BL20-B3T-SBBTension Clamp ConnectionBL20-B3S-SBBScrew Terminal ConnectionThree Terminal Block

Pagina 53 - Bus Commoning Bars

Housing Part Number DescriptionSix Terminal Block withC-ConnectionB6T-SBCSBCTension Clamp ConnectionB6S-SBCSBCScrew Terminal ConnectionBase Modules fo

Pagina 54 - Base Modules for Slice I/O

BL20Housing Part Number DescriptionThree Terminal Power Base BL20-P3T-SBBTension Clamp ConnectionBL20-P3S-SBBScrew Terminal ConnectionThree Terminal P

Pagina 55

Housing Part Number DescriptionMarkersUsed for color coding terminals onBL20 base modulesXN-ANBZ-WS (10/PKG)XN-ANBZ-GN/GE/BED (10/PKG)XN-ANBZ-RT/BL-BE

Pagina 56 - Base Modules for Block I/O

BL20-GW-ENBL20-PG-ENEthernet Gateway•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesElectrical• Operating Current:

Pagina 57

BL20Housing Part Number DescriptionLabels FW5/151-200 (10 SETS/PKG)FW5/101-150 (10 SETS/PKG)FW5/51-100 (10 SETS/PKG)FW5/1-50 (10 SETS/PKG)Numbered 151

Pagina 58 - Base Modules for Power Input

BL20BL20-GW-EN-IPBL20-PG-EN-IPEthernet Gateway•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesElectrical• Operating

Pagina 59

BL20-GWBR-CANOPENCANopen Gateway•Modular I/O•Fieldbus Independent Configuration•IP 20 Protection•Various I/O StylesElectrical• Operating Current: <

Pagina 60

BL20-2DI-24VDC-NBL20-2DI-24VDC-PBL20-4DI-24VDC-NBL20-4DI-24VDC-P(shown)Discrete Input Modules•Modular I/O•Fieldbus Independent Configuration•IP 20 Pro