5
CAUTION: DO NOT EXCEED 30 VAC INPUT ON 24 VAC
MODELS. OPERATION ABOVE 30 VAC VIOLATES LOW
VOLTAGE OPERATION (CLASS 2 SPECIFICATIONS).
NORMAL OPERATION IS 24 VAC.
CUL APPROVED 24 VAC MODELS.
CAUTION: CONNECT TO CLASS 2 POWER SUPPLY
ONLY. TOTAL CURRENT THROUGH ELECTRICAL
CONNECTOR IS 4 A MAXIMUM. PAN/TILT CURRENT IS
1 A MAXIMUM. ALLOWABLE CAMERA/HOUSING IS 3 A
MAXIMUM. USE ONLY 24 VAC CAMERAS AND HOUS-
INGS ON FEED-THRU MODELS.
3.2 Recommended Mounting Equipment
LTC 9216/00 Medium duty wall mount designed to support up
to 45.3kg (100lb).
LTC 9222/00 Heavy duty wall mount designed to support up to
90.6kg (200lb).
LTC 9214/00 Heavy duty 336mm (14 inch) column mount for
ceiling or pedestal.
LTC 9224/00 Heavy duty 610mm (24 inch) column mount for
ceiling or pedestal use.
3.3 Wall Mounting
Follow the instructions provided with mounts. Mount and mounting
surface must be able to support the weight of the pan/tilt,
camera/lens, and enclosure (if used). The camera/lens/enclosure
must be properly mounted and balanced on the pan/tilt bracket.
CAUTION: THE PAN/TILTS IN THIS MANUAL CAN
ONLY BE MOUNTED UPRIGHT OR INVERTED; NEVER
HORIZONTALLY.
3.4 Camera/Lens/Enclosure Mounting
Mount the camera/lens/enclosure to the pan/tilt bracket as follows:
1. Balance the camera/lens/enclosure and adjust the unit to align
with mounting holes. Fasten with a minimum of two (2) 1/4-20
x 1/2-inch long fasteners and lock washers.
2. Make all electrical connections. Leave sufficient loops of cable
between camera/enclosure and pan/tilt to allow for tilting and
panning.
3 INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALI-
FIED SERVICE PERSON AND CONFORM TO ALL LOCAL
CODES.
ALWAYS DISCONNECT POWER TO UNIT AT CON-
TROLLER PRIOR TO CONNECTING OR DISCONNECT-
ING PAN/TILT ELECTRICAL CONNECTOR. PAN/TILT TO
BE MOUNTED AWAY FROM UNAUTHORIZED ACCESS
[3 METERS (10 FEET) HIGH MINIMUM]
THESE UNITS ARE DESIGNED FOR EITHER UPRIGHT OR
INVERTED INSTALLATIONS. TO MAINTAIN WEATHER-
PROOF INTEGRITY WHEN MOUNTING OUTDOORS IN
AN INVERTED POSITION, THE UNIT MUST BE
INSTALLED IN A WEATHERPROOF ENCLOSURE (E.G.,
WEATHERPROOF DOMED HOUSING) OR A PROTECT-
ED OUTSIDE AREA.
Pan/tilts and associated equipment should be tested prior to field
installation to verify proper wiring and operation of components.
LTC 9418 & LTC 9420
The maximum load is 10kg (22lb) or 149kg-cm (129lb-in) torque at
a distance of 63.5mm (2.5in) from the center of mass of the cam-
era/lens/housing assembly to the center of the tilt table.
LTC 9440 & LTC 9441
The maximun load is 18kg (40lb) or 297kg-cm (260lb-in) torque
with center of mass located 3.12in (79.2mm) from the center of the
titl table.
The combined weight of the enclosure/camera/lens should be cen-
tered equally, front to back, on the tilt table surface for best
pan/tilt operation.
SEE RECOMMENDED APPLICATIONS.
3.1 Model Designation
LTC 9418 Series Load Rating:
22lb Load (10Kg), 129lb-in (149kg-cm) torque
Wiring: Standard Power Required: 24W
LTC 9420 Series Load Rating:
22lb Load (10Kg), 129lb-in (149kg-cm) torque
Wiring: Feed-thru Power Required: 24W
LTC 9440 Series Load Rating:
40lb Load (18kg), 260lb-in (297kg-cm) torque
Wiring: Standard Power Required: 20W
LTC 9441 Series Load Rating:
40lb Load (18kg), 260lb-in (297kg-cm) torque
Wiring: Feed-thru Power Required: 20W
Rated Motor Voltage Voltage Range
/60 models*: 120VAC, 60Hz 108 to 132
/20 models*: 24VAC, 60Hz 21.6 to 26.4
* 40lb Models 24VAC, 60Hz 23 to 26.4
/10 models: 24VAC, 50Hz 21.6 to 26.4
/50 models: 220VAC, 50Hz 207 to 253
Pan Range: 0
0
to 345
0
on standard models, 0
0
to 360
0
on
Continuous Pan models. Pre-position is designated as -/x1, e.g.,
LTC 9441/61