6
Screws (2)
Strain Relief Clamp
Strain Relief Slot
Shield
Washer
Wire Bundle
Sleeve
Contact
Extender
Connector
Strip Length
.156 ± .015
CAUTION: CONTACT REMOVAL FROM CONNECTOR
REQUIRES USE OF AMP #305183 EXTRACTION TOOL.
3.6 Grounding Connection
A ground screw is located on the base to the right of connector.
See
Figure 8. Connect a 1 mm
2
(No.18 AWG) ground wire to the
nearest earth ground.
3.7 Connector Assembly
A mating connector, sockets and a strain relief are included with
the unit. Refer to
Figure 1.
To install, select the appropriate size strain relief clamp. Choose
one of the two strain relief clamps enclosed with the sleeve and the
extender. The clamping area is adjustable by inverting or changing
the strain relief clamps. Discard the four strain reliefs on the
carrier strip packaged with the shield.
Insert the clamp into the strain relief until it bottoms. The clamp
should bottom on the wire bundle, not on the shield’s shoulder. If
the wire diameter is too small, temporarily wrap the wire with elec-
trical tape until proper clamping is obtained. Secure the clamp with
the two (2) screws provided.
CAUTION: MAKE SURE THE WIRE BUNDLE IS PROPERLY
SECURED. DO NOT PINCH THE WIRES.
3.5 Electrical Connections
1. Cable must be wired according to Connector Assembly
(Section 3.7) and Recommended Maximum Cable Lengths
(Table 1).
2. Use separate shielded cables for camera power, enclosure
power, and pan/tilt control. If required, combining lens control
wiring and video coax within a common cable is acceptable.
The use of a common multiconductor cable to combine all
functions is not recommended.
3. Use color coded conductors to aid wiring and future identifi-
cation.
4. Retain wiring diagram for later reference.
Notes For Table 1
1. Values calculated at 20º C (68 ºF) using stranded tinned copper
wire, a common ground (neutral), and both PAN and TILT motors
operating simultaneously.
2. For 24 VAC Models operating at or near -30º C, values are
based upon maintaining the supplied voltage within the voltage
range as specified in Section 3.1.
AMP Hand Crimping Tool #58495-1 is recommended for crimping
sockets. Refer to
Figure 2 for the numbered connector
positions.The connector will accept up to a #16 AWG wire. If heav-
ier gauge wire is required, pigtailing according to local electrical
codes is recommended.
Model Wire Size Distance
1
Voltage mm
2
AWG Feet Meters
24 VAC
2
0.5 20 140 43
118 230 70
1.5 16 360 110
2.5 14 590 180
412 940 287
110 VAC 0.5 20 2200 671
118 3500 1067
1.5 16 5500 1677
2.5 14 9000 2744
220 VAC 0.5 20 13400 4085
118 21200 6463
1.5 16 33300 10152
2.5 14 54400 16585
Figure 1: Shield/Strain Relief Assembly
Table 1 Maximum Cable Lengths