Solution 16 i
22
Bosch Security Systems 09/07 BLCC500R FTR1.02
Quick Start Guide
Copyright © 2007 E&OE
3) The Panel Will Reset And Revert To Normal
Operation When Defaulting Is Complete.
FDEF ?
Figure 29: Factory Default Display
i
Note
You can disable factory defaulting using MENU 7-7-
4. If factory defaulting has been disabled you must
know the installer code to perform a factory default
otherwise the system will need to be returned to
your supplier for defaulting or you can purchase a
CM255 Default Unlock Key which will unlock the
panel in the field. Charges apply for defaulting if
retuned to the distributor.
DOMESTIC TEMPLATE DEFAU LTS
The following table list the changes that will occur when
you select domestic default.
Program Option Domestic Default Value
All Trouble Reports Disabled
All Bypass Reports
Disabled
All Restore Reports
Disabled
Destination 1 TX Format Domestic Reporting
Open / Close Reports Disabled (all areas)
System Events Route Log Only
Table 14: Domestic Dialing Defaults Settings
DIREC T LI NK PRO GRAMMING
The panel can be programmed via the Solution Link
Upload/Download software in either Direct Link or Remote
Link modes. For Direct Link you will need a CM900 Direct
Link module which connects the panels serial port to the
PC.
Once the cable is connected you will need to hold down
the default switch on the panel for 5 seconds to initiate the
programming session. See Figure 12: for the default switch
location. It is also possible to initiate the programming
session via [MENU 5-0-5] Start Direct Link.
Solution Link V1.10 or higher is required to program this
panel.
ZO NE ARR AY
The feature allows you to view the condition or status of all
zones on the panel in groups of 4 zones at a time. Use the
[] and [] keys to change the group of zones to display.
The starting zone for each group is displayed at the
beginning of the screen so you will always know which
zones you are viewing.
Use Keys [] and [] to scroll up and down the zone bank
Press [OK] or [MENU] when finished.
N= NORMAL
S = SHORTED
A= ALARM
T= TAMPER
- = DISABLED
01nSAn
Figure 30: Zone Array Showing Z1 to Z4
09-nST
Figure 31: Zone Array Showing Z9 to Z12
In the above example screens,
N = Zone 01, 04 and 10 are Normal (Sealed)
S = Zone 02 is Shorted
A = Zone 03 is in Alarm (Unsealed)
T = Zone 12 is in Tamper Alarm (Unsealed)
- = Zone 09 is Disabled (Unused)
BASIC REPOR TIN G R EFE REN CE
A complete reporting template is available on the Solution
Link CD, from your distributor or from Bosch. Your base
station will need to create a specific reporting template for
this and other 2nd generation Solution panels.
Point ID Table Module Description
Ur999 Installer
Ur998 Remote User
Ur001 - 256 Users
Ur000 Quick Arm
Zn301-428 User Keyfob 1 - 128
Zn891-898 Panels 1-8
Zn881-888 Keypads 1-8
Zn871-878 Ethernet 1-8
Zn861-868 GSM 1-8
Zn851-858 Output Expander 1-8
Zn841-848 Serial Expander 1-8
Zn831-838 Lan P/Supply 1-8
Zn821-828 RF Reciever 1-8
Zn811-818 Access 1-8
Zn801-808 X10 1-8
Zn781-788 Input Expander
Zn791-798 Lift 1-8
Zn001-128 Zones
Table 15: Basic Reporting Code Reference Listing