Access Control Interface Module System Overview | en 9
Bosch Security Systems, Inc. Installation and Operation Guide F.01U.215.244 | 05 | 2012.06
Locked Door. This state is considered a normal door state.
Unlock Door. This state allows the door to be opened for free access.
Secure Door. This state will not allow access unless a Fire Unlock occurs.
Fire Unlock. This state allows free access no matter what the previous door state or
armed state is. This is a programmable option that can be used to allow free access into
the building upon a fire alarm.
Automatic Functions and Door State. The interface module has two automatic functions that
control door state based on the armed state of the area:
Auto Door. With this function as [YES], the door will be unlocked when the area is
disarmed.
Disarm on Open. With this function as [YES], a user with valid access rights will activate
the strike and disarm the system after the door is opened. With this function as [NO], the
area will disarm upon the strike activation.
2.1.7 Access Levels
Armed State Rights. Users can be prevented from access depending upon the armed state of
the area that the interface module is assigned to. M indicates the user has access no matter
what the armed state, P indicates the user has access as long as the area is perimeter armed
or disarmed, and D indicates the user only has access when the area is completely disarmed.
Disarm Access Level. Users are allowed to disarm the area with an access identification. Care
should be taken to ensure that the user first has the authority to activate the strike based on
the Armed State. P indicates the user will disarm the area from Master to Perimeter Instant. D
indicates the user will disarm the area from Master or Perimeter to the disarmed state.
Unlock Door. Provides an automatic free access at a specific time period. Requires a Lock
Door Sked to return the door to normal. Can be overridden by manual control at the control
center.
Secure Door. Provides an automatic prevention of access at a specific time period. Requires a
Lock Door Sked to return to normal. Can be overridden by manual control at the control
center.
Lock Door. Provides an automatic lock door state at a specific time to return the door to
normal requiring valid cards or tokens to allow access.
Message Suppression. Provides an automatic message off or on function at a specific time for
Door and Access Granted or No Entry messages.
Access Ctl Level On/Off. Provides an automatic on or off for each of the 14 levels dealing
with the access control. Once a level is turned off, all doors are affected.
Diagnostics. Patterns of LED activation indicate door state and identification validity. Other
indications include SDI failure.