Bosch DIVAR AN 5000 Manual de usuario Pagina 68

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 162
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 67
System events
Figure 6.30: System events
Use this menu to setup how the system reacts to different system events.
Event type: choose from disk error, no disk, no space on disk, NET disconnection, IP
conflict, MAC conflict.
Enable: select to enable the system event.
Alarm out: select the alarm activation output port(s) (maximum of 3 on DIVAR 3000; 6 on
DIVAR 5000).
Latch: set a delay time (from 10 seconds (default) to 300 seconds) before the system
automatically turns off the alarm and the activated output after the external alarm is
cancelled.
Show message: system will pop up a message on the local screen to alert you when an
alarm occurs.
Alarm upload (this option is only shown for the events ‘no disk’ and ‘no space on disk’):
system will upload the alarm signal to the network.
Send email: system will send an email to alert you when an alarm occurs.
Buzzer: the buzzer alerts you when an alarm occurs.
6.14
68 en | Configuration DIVAR AN 3000 / DIVAR AN 5000
2013.11 | 1.1 | AM18-Q0669 Operator Manual Bosch Security Systems
Vista de pagina 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 161 162

Comentarios a estos manuales

Sin comentarios