4-4 Motion control configuration Rexroth SYNAX 200
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
4.2 MotionControl PPC-R
Rexroth
H1
PROG
U2
X10
X1
Q1
Q2
24V
e
0V
e
Bb
Bb
24V
0V
S1
RX
TX
U1
S2
RESET
H2
DIST
COM
X16
U3 U4
8888
I1
I3
I2
PPC-R22.1
1212
7
5
4
3
1
2
6
13
10
11
9
8
PPC-R22.1
8
7
13
12
11
10
9
6
5
4
3
2
11
Key for display switchover
or other usage
Slot for the PC card-compatible
firmware module
Reset key S2
Distortion display H2
for SERCOS interface
Fibre-optic emitter
for SERCOS interface
Fibre-optic receiver
for SERCOS interface
X1 voltage supply and
watchdog
Status display H1
Optional slot
X16 Programming interface (COM)
X10 Serial interface (PROG)
Earthing bolt
X15 BT bus for connecting
up to 6 devices (PLC only)
Ethernet connection
YG000068V01_EN..FH7
14
14
Fig. 4-5: PPC-R22.1
The PPC-R unit is a powerful controller in a small size in IP 20 rating. It is
a general-purpose platform that works as a PLC or as a NC controller,
depending on the application and the loaded software.
The PPC-R unit exists with two enclosure versions of different width. A
single-width version and a double-width version.
The two interfaces that are available on the controller are fully connected
according to the Rexroth standard (SIS = Serial Indramat Interface). The
data transfer type (function) is only selected by the related application
(RS232/RS422/RS485). With PPC-R21, the COM interface is brought out
via a separate slot plate if this has not yet been assigned for a different
purpose (by the PC/104 fieldbus, for example).
To install the PPC-R unit, a module carrier system is used that consists of
one or several RMB02.2-04 units. The double carrier RMB02.2-02 can
only be used as an installation carrier. It is merely used for fixing the
PPC-R units; RECO modules cannot be controlled. Interconnecting
several PPC-R units via a backplane is not possible either.