Bosch DS7200V2-EXP Guía de usuario Pagina 147

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 146
DS7200V2-EXP | Expert Programming Guide | 5. Reference Materials EN | 147
Bosch Security Systems | 8/04 | 4998153891C
Table 31: Control Panel Events and Reporting Formats (continued)
Event Event as shown in
Control Panel Log
SIA Report Contact ID
Report
Event Description Zone Types
Linked to Event
RPS
Event
Group
Status
Report
179 UnBypss,Ctrl,RPS
BU Burglary
Unbypass
570
Zone/Sensor
bypass
Bypass on zone type cleared using
RPS (un-bypass)
10 to 15- Zone
Types
180 UnBypss,24hr,RPS
BU Burglary
Unbypass
572 24 hour
zone bypass
Bypass on 24-hour zone type
cleared using RPS (un-bypass)
3 to 9- 24-hour,
Non-Fire Zone
Types
181* RF Battery Low
XT Transmitter
Battery Trouble
384 RF Low
Battery
Low battery condition on RF
Keyfob.
9 R
182* RF Battery Rstl
XR Transmitter
Battery Restoral
384 RF Low
Battery
Low battery condition on RF
Keyfob restored.
9 R
183 Trbl,Default PIN Local Event Only
Local Event
Only
Installer or User PINS have not
been changed from default.
184 Rstl,Default PIN Local Event Only
Local Event
Only
Installer or User default PINS have
been changed.
185 Failed to Arm EE Exit Error
454 Failed to
Close
Arming attempt failed. 3
186 Verified Alarm
BV Burglary
Verified Alarm
139 Intrusion Verified Alarm. 3
187 Dbus Missng Alrm TA Tamper Alarm
137 Tamper
Alarm
Data bus device not responding to
polling. (Shows Zone 41)
12 R S
188 Dbs Mis Alm Rstl
TR Tamper
Restoral
137 Tamper
Alarm
Data bus device declared as
missing now responding to polling.
(Shows Zone 41)
12 R S
189 Dbus Tamper Alrm TA Tamper Alarm
137 Tamper
Alarm
Tamper open on Data bus Device
Tamper. (Shows Zone 42)
12 R S
190 Dbs Tmp Alm Rstl
TR Tamper
Restoral
137 Tamper
Alarm
Data bus device tamper restoral.
(Shows Zone 42)
12 R S
191 Dbus Trouble Alm TA Tamper Alarm
137 Tamper
Alarm
Trouble detected on data bus
device. (Shows Zone 43)
12 R S
192 Dbs Trb Alm Rstl
TR Tamper
Restoral
137 Tamper
Alarm
Data bus device trouble condition
cleared. (Shows Zone 43)
12 R S
193 Siren Missg Alrm TA Tamper Alarm
137 Tamper
Alarm
Trouble condition detected on PO
2 configured as supervised siren
output. (Shows Zone 44)
12 R S
194 Siren Alarm Rstl
TR Tamper
Restoral
137 Tamper
Alarm
Trouble condition on supervised
siren output cleared. (Shows Zone
44)
12 R S