DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 58
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 10: System Functions 2
• Address: 0373
• Default: 3
• Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 10: System Functions 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
•
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
• • • • • • • •
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the following functions by authority level:
• Set Time and Date (send Date/Time Change {73} report) ([#][4][5])
• Change Skeds ([#][5][2]) (see Sked Parameters on page 120 for more information)
• Renew One-Time PINs ([#][5][3])
• Change (Add) Other PINs ([#][5][6])
• Delete PINs ([#][5][8])
• Set Chime Tone ([#][6][2])
• Set Chime Zones ([#][6][3])
• Set Partial On Zones ([#][6][5])
• Auto-Call Forwarding Enable, Digits to dial at All On ([#][8][3])
• Auto-Call Forwarding Disable, Digits to dial at disarm ([#][8][4])
• Reset tampers/troubles ([#][4][7]) [Also requires authority level option 9)
1
• Enable Installer PIN ([#][9][2])
2
1
Enable this parameter for each user that can reset tamper and major trouble conditions (see Tamper Reset/Arming
Options on page 44).
2
Set this parameter for each user who can enable the Installer PIN. For more information, see the “Restrict
Installer PIN” option in Keypad Response Options on page 70.