SMS configuring LEDs
Condition B450
Heartbeat
B450 Transmit
(TX)
B450 Receive
(RX)
Plug-in module
status
Invalid SMS message
received
1 sec flash The Transmit (TX) and Receive (RX)
LEDs will alternate flashing at 1/2
second interval
1 sec flash
SMS configuration
complete
1 sec flash The Transmit (TX) and Receive (RX)
LEDs will flash in unison at a 1
second interval
1 sec flash
Show the firmware version
To show the firmware version using an LED flash pattern:
the optional tamper switch is installed:
With the enclosure door open, activate the tamper switch.
If the optional tamper switch is NOT installed:
Momentarily short the tamper pins.
When the tamper switch is activated (open to closed), the heartbeat LED stays OFF for 3 sec
before indicating the firmware version. The LED pulses the major, minor, and micro digits of
the firmware version, with a 1 sec pause after each digit.
The following is an example: The version 1.4.3 would be shown as LED flashes:
[3 second pause] *__****__*** [3 second pause, then normal operation].
Figure 6.1: Firmware LED flash patterns example
Diagnostic log
The Diagnostic Log option is used in the event of an intermittent service outage, or
communication error, in which a diagnostic log can be generated from the B450 menu options.
The generated diagnostic log file is used by TECHNICAL SUPPORT to determine how often a
persistent problem occurs, as well as detailed network configuration settings associated to
the module during the time of the reported problem.
Generate the diagnostic log only when directed by TECHNICAL SUPPORT.
Understanding network polling
Plan carefully when programming the control panel poll time, ACK wait times, retries, and
D6x00 Receiver poll and supervision time. Having the wrong or improper control panel
settings could cause trouble conditions when the network carrier performs maintenance, and
increased data volumes that could effect your monthly cost. Your settings for these
parameters determine how the system works, but depend on the security level needed.
For more information regarding proper data plans and installation parameters related to
network polling, refer to Bosch Cellular Service User Guide (P/N: F01U273558).
6.2