RMING PIN CODES AND AUTO-ARM
Because Auto-Arming is a global setting in the g! system, All Bosch panels must have the same settings
for the Auto-Arm mode. Panels/partitions that are set to Auto-Arm will not arm from the g! system if a
PIN number/enter key combination is specified in the Configurator. Make sure that your Bosch
programming matches your settings in g! Configurator for number of keys and Auto Arm or you
will not be able to arm/disarm from g!!
If it is desired to require a PIN to be entered into the g! system to arm the panel, the Bosch panels must
be configured to require the following key presses to arm: [COMMAND] + [MODE (number)] + [CODE
(arming code)] + [ENT].
Note that your PIN settings may vary depending on the Arm Modes as well.
For instance, Master Arm (Mode 1) may not require a PIN to arm and should have Auto Arm set to ‘Yes’
in Configurator, while Perimeter (Mode 3) may require a 6 digit pin and should have Auto Arm set to ‘No’
and number of keys set to ‘6 keys’ in Configurator.
K
EYPAD SETUP AND PARTITIONS (AREAS)
The following special steps are needed to make sure that the g! system can successfully arm and disarm
the security system:
There must be an area-wide keypad programmed for each partition (area).
The address of the keypad for partition 1 must be 1, the address of the keypad for partition 2
must be 2, and so on.
If you have “Panel Wide” keypads that can access more than one partition, set the address to
a number greater than the number of partitions.
Consider the example of a property that has two partitions: partition 1 - the main house and partition 2 -
the guest house. The following is one possible arrangement of keypads:
A keypad is installed by the front door, to arm and disarm the main house, partition 1. The
keypad is not a master keypad (it cannot arm or disarm the guest house), and is set with an
address of 1.
A keypad is installed in the guest house, and it has an address of 2. Like the keypad in the
main house, the keypad in the guest house cannot arm or disarm the main house.
A third keypad is installed in the master bedroom. It is a master keypad and can arm or
disarm either the house or guest house. It has an address of 3.