Bosch D9000, G Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 6
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5 of 6
g! CONFIGURATION DETAILS
The following table provides settings used in the g! Configurator. Please refer to the Configurator Reference Guide for more details.
o “<Select>” Select the appropriate item from the list (or drop-down) in the Configurator.
o “<User Defined>”, etc. Type in the desired name for the item.
o “<Auto Detect>”, etc. The system will auto detect this variable.
o “<Defined in Security System>” The security installer must provide the information to you.
Devices Variable Name Setting Comments
Communication Devices Name
<User Defined> (Default:
Security
)
Type Serial Port
Communication Type Standard Connection
Location
<User Defined> (Not Required)
Com Port
<Select>
Security Panels Name
<User Defined> (Default:
Bosch/Radionics D7412G,D9412G
)
Device Type Bosch/Radionics D7412G,D9412G
Location
<User Defined> (Not Required)
Comm Device
<Select> (Default:
Security
)
Name Show Auto Keys
Disarm Disarm Yes NO # of Keys Set as appropriate (4 keys for 4 digit code, etc.)
Mode 1 Master Yes YES NA
Mode 2 Perimiter Yes NO # of Keys Set as appropriate (4 keys for 4 digit code, etc.)
Partions Name
<Auto Detect>
User Number
<Auto Detect> Do not change this setting: this is the partition number.
Zones Name
<Auto Detect>
Enable Bypass
<Defined in Security System> (See Note 1)
Select Partitions
<Select>
(See Note 2)
Notes:
1. The
Enable Bypass
variable must set to
Yes
in order to enable this feature for a zone. The zone must also be bypassable in the security panel for this feature to function.
2. Verfiy that the correct partitions are selected for each zone.