– 40 –
Testing your System (continued)
Battery Tests
If a power failure occurs, your control panel has a built-in battery that will continue to power the control panel for many hours. The control
panel automatically recharges the battery when power is restored.
In addition to an automatic battery test performed every 2 minutes, the battery may also be tested manually. This test also uses the battery to
manually activate all the system sounders for 2 seconds ([PIN] [#] [8] [5] only). If the battery voltage is low, a battery fault will occur (see Error
Displays).
If this test is performed from a Master keypad, it must be in Single Partition Mode. System Tests are not available from RF (wireless) keypads.
Type of Test
Sequence
What Will Happen What To Do
Local Battery /
Sounder Test
[PIN] + [#] [8] [5]
•
All keypad LEDs will turn on.
•
The keypad sounder and all alarm
sounding devices will operate for two
seconds.
•
If the test fails, the control
panel will indicate a control
problem. See Error Displays.
•
If the power in your buiding
has been off recently, wait two
hours for the battery to
recharge and then try again.
Battery Test
[PIN] + [System
Reset]
•
The control panel will perform a battery
test.
•
The control panel will report a Low
Battery or a Low Battery Restoral is
necessary.
Comentarios a estos manuales