ICP-CC404 | User's Guide | 21.0 Basic Pager Reporting
Bosch Security Systems, Inc. | 12/08 | F01U089400-02 15
Table 12: Zone Status Display Descriptions
Display Zone Description
0 Normal. The corresponding zone is sealed.
1 Alarm. The corresponding zone is unsealed
and in alarm.
2 Bypassed. A system operator manually
isolated the corresponding zone. Refer to
Section 9.0 Isolating Zones for information
about manually isolating a zone(s) before
arming the system.
3 Trouble. A zone was unsealed when Exit Time
expired.
System Status
The system status information is divided into the four
digits identified in Table 13.
Table 13: System Status
Digit Description
First 8 = the system is disarmed
9 = the system is armed
Second Identifies the codepad alarm activated by the
operator:
0 = No Codepad Alarm
1 = Codepad Panic or Duress Alarm
2 = Codepad Fire Alarm
3 = Codepad Medical Alarm
Third 0 = AC Supply is normal
1 = AC Supply failed
Fourth 0 = System Normal – There are no faults.
1 = System Fault – The control panel
registered a fault.
Figure 6 on page 16 shows a transmission from a
control panel with an ID number of 678, and Zone 2
in alarm. Figure 6 on page 16 also shows Zone 3 is
manually isolated and the system is armed.