ICP-CC404 | User's Guide | 4.0 Arming the System
6 Bosch Security Systems, Inc. | 12/08 | F01U089400-02
3.5 MAINS Indicator
The MAINS indicator shows if the
systems AC MAINS supply is normal or
failed.
Table 4: MAINS Indicator
Status Definition
On AC MAINS power normal.
Flashing AC MAINS supply failed.
3.6 Off Indicator/Zone Sealed
The
indicator lights when the
system is disarmed and flashes when a
zone becomes unsealed when
disarmed. The indicator stops flashing
when all zones are sealed.
3.7 On Indicator/Zone in Alarm
The
indicator lights when the
system is armed in AWAY Mode and
flashes when an alarm occurs. The
system resets this indicator after you
enter a valid user code.
3.8 FAULT Indicator
The FAULT indicator lights if the
system detects a system fault. Refer to
Section 11.0 Fault Analysis Mode on
page 11 for additional information on
system faults.
Every time a new system fault is
detected (the FAULT indicator flashes),
the codepad beeps once every min.
Pressing [#] once cancels the once a
min beep and acknowledges the fault
(the FAULT indicator lights steadily).
Table 5: FAULT Indicator
Indicator Definition
On There is a system fault you must correct.
Off The system is normal. There are no faults.
Flashing There is a system fault that must be
acknowledged.
3.9 Audible Indications
Table 6 defines the audible indicators generated by
the codepad buzzer.
Table 6: Audible Indicators
Indicator Definition
One short beep A button was pressed on the
codepad, or end of Exit Time
occurred when armed in STAY
Mode 1 or STAY Mode 2.
Two short beeps The system accepted your code.
Three short beeps The system executed the requested
function.
One long beep Indicates the end of Exit Time when
armed in AWAY Mode, or the
requested operation was denied or
aborted.
One beep every
sec
Walk Test Mode is currently active
or it is a warning before automatic
arming takes place.
One short beep
every min
There is a system fault waiting to be
acknowledged.
4.0 Arming the System
There are several ways to arm the system depending
on whether you are:
Leaving the premises and you want all active
zones to be in a ready state for an intruder.
Remaining in the premises and you only want
part of the system to be in a ready state for an
intruder.
If a zone is not sealed at the end of Exit Time, the
zone is automatically isolated and lights steadily on
the remote codepad. The zone becomes an active
part of the system when the zone is resealed. For
example, if a window is left open after Exit Time
expires, the window is not an active part of the
system until the window is closed. Opening the
window after Exit Time expires causes an alarm.
Table 7 defines the different methods for arming the
system.
Table 7: Arming Methods
Method Definition
AWAY Mode
Arms the entire system. Refer to
Section 4.1 Arming in AWAY Mode.
STAY Mode 1
Arms all zones except those
programmed by the installer to be
automatically isolated. Refer to Section
4.2 Arming in STAY Mode 1.
STAY Mode 2
Arms all zones except those
programmed by the Master Code
holder to be automatically isolated.
Refer to Section 4.3 Arming in STAY
Mode 2.