CCTV | Allegiant® Matrix Switcher Systems | Selection Guide | May 2009
www.boschsecurity.us 800.289.0096
Next select a quantity of LTC 8621/00 Video Input Modules
(VIMs) and LTC 8834/00 Video Output Modules (VOMs)
that will be required to satisfy your system capacity
requirements according to the charts below:
For medium to large sized, modular based
Allegiant systems.
• Modular construction using individual Video Input
Modules and Video Output Modules offers the
convenience of variable system sizes. The LTC 8600
system offers increments of 16 camera inputs and 4
monitor outputs up to a maximum system capacity of 128
cameras by 16 monitors.
• Optional external alarm and remote control signal
distribution accessory devices available.
• Full control and programming by up to 16 keyboards.
• RS-232 Serial port for external PC interface.
• RS-232 Printer port for external logging printer.
• Integral 6-U high rack enclosure.
• 2-digit site and 4-digit camera identication mode.
Ordering Information:
Ordering main system components involves only 3 part
numbers. First, select the appropriate main CPU bay model
based on AC line voltage requirements as listed below.
LTC 8600 Series
Main CPU Bay AC Line Voltage
LTC 8601/60 120VAC, 60 Hz
LTC 8601/50 230VAC, 50Hz
LTC 8621 VIM and LTC 8834 VOM Quantities
LTC 8621/00 Input Modules LTC 8834/00 Output Modules
Camera
Quantity
VIM Module
Quantity
Montor
Quantity
VOM Module
Quantity
1 to 16 1 1 to 4 1
17 to 32 2 5 to 8 2
33 to 48 3 9 to 12 3
49 to 64 4 13 to 16 4
65 to 80 5
81 to 96 6
97 to 112 7
113 to 128 8
Optional accessories:
If looping video inputs will be required, include one LTC
8808/00 Video interconnect panel for each group of 32
cameras.
If external contacts will be utilized to activate alarm video
switching, LTC 8540/00 Alarm Interface Units and, if
necessary, LTC 8713/x0 Alarm Port Expander Units can be
added to the system. Follow the table below to determine
the appropriate quantities required.
Alarm Interface and Alarm Expander Quantities
Alarm
Inputs
LTC 8540/00
Alarm Unit Quantity
LTC 8713/x0
Expander Quantity
1 to 64 1 0
65 to 128 2 1
129 to 192 3 1
193 to 256 4 1
257 to 320 5 3
321 to 384 6 3
385 to 448 7 3
449 to 512 8 3