Praesideo PRS-CSM / PRS-CSRM / PRS-CSKPM en | 10
Bosch Security Systems B.V.
IUI PRS-CS(R)(KP)M | V1.0 | 2013.12
Installation and User Instructions
It is also possible to connect an externally powered
lamp or LED (see figure 1.11), or an externally powered
relay (see figure 1.12). Use pin 2 of connector 5 as GND.
The value of resistor R in figure 1.10 depends on the
voltage of the external source, the forward voltage of the
LED and the current flowing through the LED:
For example, the voltage of the external source is 24 V,
the forward voltage of the LED is 2 V and the current
flowing through the LED is 10 mA, then:
figure 1.11: Externally powered LED
figure 1.12: Externally powered relay
Max. 56V
R
LED
indicator -/cathode
GND
I < 100 mA
R
V
source
V
forward
–
I
---------------------------------------------
=
R
24 2–
10 10
3–
⋅
---------------------
2200 Ω()==
LED
indicator -/cathode
GND
Max. 56V
I < 100 mA