Bosch CS 150 RC Manual de instrucciones Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
Praesideo PRS-CSM / PRS-CSRM / PRS-CSKPM en | 7
Bosch Security Systems B.V.
IUI PRS-CS(R)(KP)M | V1.0 | 2013.12
Installation and User Instructions
1.2.1 Back-up supply/Buzzer (1)
This 4-pin connector provides the input for a backup
power supply and a buzzer. Typically a 24V supply is
used, but a voltage in the range 18..56V is allowed.
A buzzer can be connected here for fault and alarm
notification. A low voltage type buzzer must be used
that can operate on 3V. Suitable models are the Mallory
PK-20A35EWQ or Alan Butcher Components ABI-004-
RC.
1.2.2 Microphone/PTT key connection
(2)
This 6-pin connector provides the connection for a
microphone and a PTT key. The following dynamic
microphones are suited for use with the module:
LBB9081 Hand-held Dynamic Microphone
(including resistors for switch supervision).
LBB9082 Gooseneck Dynamic Microphone.
For the selection of the microphone type, a jumper on
X149/X150 is used. To get access to this jumper,
remove the top cover (see also section 3.3). For the
location of X149 and X150 on the PCB see figure 1.13.
Jumper settings:
Microphone selection via
configuration webpage
Dynamic microphone
Electret microphone
table 1.1: Back-up supply/buzzer connector details
Pin Signal
1 Back-up supply (+)
2 Back-up supply (GND)
3 Buzzer (+)
4 Buzzer (-)
table 1.2: Microphone/PTT key connector details
Pin Signal
1Mic +
2 GND
3Mic -
4 --- not connected ---
5 PTT input contact
6 GND
figure 1.4: LBB9081 connection diagram
10k:
10k:
blue
black
red
white
black
(thick)
5
6
1
3
2
figure 1.5: LBB9082 connection diagram
3
1
2
black
white
red
12
12
3
12
12
3
12