1.3.4 BOSH GV2 NETWORK REQUIREMENTS
BOSH GV2 ETHERNET MODULE SETTINGS:
ThisinformationappliestoBosch9000/7000SeriespanelsGV2andGV3V8.11OROLDER .Panelsconnect
toGalaxybythreepossiblemethods;(a)Ethernet
,(b)RS232directconnect,orby(c)LantronixIP/Serial.
a) (
CHOICEA)EthernetDevice(mostcommon)DX4020Module:Boschinstallermustsetupthe
moduleincludingthefollowingknownrequirements:
FollowwiringinstructionsfromtheBoschinstalldocumentation.
DIPswi tchsettings:1thru6and8=down/offand7=up/on
a. Flowcontrol=none
b. UDPdatagram=disable(touseTCPIP)
c. teln
etport=9999
d. Setconnectmodeto“C0”(C,zero)insteadof“CC”;
Supportsencryption‐specialconfigurationinfointheBoschmanuals.Thisissetatthe
moduleviatelnetandmustbesetontheSystemGalaxyendintheAlarmPanelService
screen.WhateverissetatDX2040mod
ulemustmatchthesettingintheAlarmPanelService.
SeeSection8forhowtoconfigureencryptionattheAlarmPanelService.
keylength=128(default);mustbezeroifnotused.
Mustspecifyakeyvalue:thekeyvalueisa16digi
thexcode;mustbeblankifnotused.
Example:‘’01020304050607080910111213141516’isanexampleofa16digithex
code,whichisactually32characterslong;ahexdigi tis madeof2characters.
Validhexcharactersare:0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,F.Thereforeahex
valueof‘01’=1and‘0A’=10whe
nconvertedtodecimalvalue.
b) (
CHOICEB)DirectconnectusingRS232ConnectionModulesuchastheModelDX4010i:theRS‐
232moduleprovidesserialconnectiontoSystemGalaxyCommunicationServer(PC).The
CommunicationServerisdefinedasthePCwherethemainGCSServicesreside.
WiringinfoisintheBoschInstalldocumentationforcomtopanel
DIPSwitchsettingsare1,2,3,4=UPand5,6,7,8=DOWN
9600Baud,nopa
rity,8bit,1stopbit
UsesDB9RS232cabletoconnecttoPCcomport
PinOutforRS‐232Cable
DB9female DB9female
2 3
3 2
5 5
c) (
CHOICEC)LantronixIP/SerialDirectConnect:usingserial(asabove)andIPontheSGcommside.
ConfigureLantronixdevicethesameaswithNetworkBridgeforaRemotePrimary508
panel.SeetheLantronixmanualforconfigurationinformation.