Galaxy Interface Manual for Bosch G-series Alarm Panels
Page 16 of 39
2.5 Adding an Alarm Panel Area
The Alarm Panel Area should be added in the System Galaxy software. The programming must match
the Alarm Panel Area configuration. An alarm panel area consists of 1 or more points
After Panel, Areas and Points are added, System Galaxy can begin receiving status events from the
alarm panel. (Note the alarm panel connection must be maintained). The alarm panel events are
displayed in the Alarm Panel Event screen.
1. open the Alarm Panel Areas Property screen (Configure>Hardware>Alarms>Alarm Panel Areas)
2. pick the desired alarm panel name from the Select Alarm Panel droplist
3. click the Add New button and set the following fields as needed:
Name field: type a descriptive name (preferably that matches the panel)
Area Number: enter the area number that matches the area in the alarm panel
(1-8)
Show in Tree: the show in tree checkbox allows Alarm Panel Area Icon to display in the
System Galaxy Hardware Tree.
4. click the Apply button to save changes
NOTE: The SG Hardware Tree may need to be refreshed to pick up the Area Icon. To refresh
the hardware tree, simply close the tree’s window pane by clicking the [x] button at the
top and reopen it from the SG View menu (select View>Hardware Tree).
NOTE: The Alarm Panel Area Icon will display under the specific Alarm Panel Icon to which it is
assigned. Expand the Alarm Panels Icon, and then expend the Alarm Panel Icon to see
the Alarm Panel Area Icon.
Alarm Panel Area Property screen (cropped)