
© Radionics Inc. reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
73
PA 0197
A/C Fail Report Delay Programming
The A/C Fail Delay Times are
programmed as Hexadecimal
values.
Example:
00 Send only with next report
1*4 30 Minute Delay
3*2 60 Minute Delay
78 120 Minute Delay
*5*5 Random Delay
(at least 15 but less than 120)
We count 0-9
Hex counts 0-15
To us 30 means 3 tens and 0 ones or
(30 units)
To Hex 30 means 3 sixteens and 0
ones (48 units)
3*2 = 60 because
3x16 equals 48
and *2 equals 12
60
DS7400Xi Panel Wiring & Programming
Data Digit
1 2
0 0
A/C Fail Report Delay
Address 0197
00 through FF
Comentarios a estos manuales