Bosch DS7400XiV4-EXP Especificaciones Pagina 109

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 108
DS7400XiV4-EXP | Reference Guide | 7. Reference Materials EN | 109
Bosch Security Systems | 1/05| 4998154963B
7. Reference Materials
7.1 Addressing Multiplex Zones
This section does not apply to the following
multiplex devices:
DS7457i/DS7457iF
DS7460i
DS7461i
DS7465i
See the documentation for these devices
for addressing instructions.
Before installing a multiplex device, its address and
other information must be entered into the control
panel.
If you are using a DS7436 Multiplex
Expansion Module, program it using Bus A.
7.1.1 Control Panel Setup
Before a multiplex device address can be entered into
the control panel, the control panel must be properly
programmed. See Programming a Zone on page 31 to do
the following:
1. Assign a zone number
2. Assign a zone type
- Single zone input
- Multiple zone input
- DS7465 input/output module
- Multiplex smoke detector
- Multiplex smoke detector with low temperature
alarm
3. Assign which zone function or output function the
multiplex zone follows
4. Assign an area/partition to the multiplex zone
For example, the following steps show how to program
Zone 9 as a single zone input device (MX950) that
follows Zone Function 1 and is assigned to
Area/Partition 1.
1. Enter the programmer’s mode.
2. Enter Address 0039.
3. Press [0][1][#] to program Data Digits 1 and 2
(Data Digit 1 = 0; Data Digit 2 = 1).
4. Enter Address 0291.
5. Press [0][0][#] to program Data Digits 1 and 2
(Data Digit 1 = 0; Data Digit 2 = 0).
6. Exit the programmer’s mode.
7.1.2 Multiplex Device Setup
When the control panel is properly set up for
multiplex zones, you can begin programming
multiplex devices.
1. Disconnect all multiplex devices from the DS7430.
2. Program the multiplex devices from the control
panel.
a. Enter the programmer’s mode.
b. Enter the multiplex programming mode by
pressing [9][9][9][5][#].
The control panel checks the multiplex
connection to confirm that nothing is
connected. The text keypad shows:
Checking
Multiplex Bus
The display then scrolls to the first zone you
entered as a multiplex zone.
To scroll to a different zone, press [Reset/*],
and then enter the desired three-digit zone
number. The text keypad shows:
Sens/Contact 009
Press # to Prog
c. Reconnect the multiplex device that coincides
with the displayed zone to the DS7430.
d. Press [#] to enter the device into the control
panel.
If you are programming a DS7465 or a
multiple input device, these device types
require two zone addresses. For example, if
Address 009 is assigned to a DS7465, the
DS7465 will also occupy Address 010 when
you press [#].
Vista de pagina 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 143 144

Comentarios a estos manuales

Sin comentarios