DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 50
Bosch Security Systems | 1/05| 4998154963B
Table 61: Custom Arming Programming (Address 2728, Data Digit 1)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Bypass Zone Function 25
Bypass Zone Function 26
Bypass Zone Function 27
Bypass Zone Function 28
Table 62: Custom Arming Programming (Address 2728,
Data Digit 2)
Selections for
Data Digit 2
Select Options 0 1 2 3
Bypass Zone Function 29
Bypass Zone Function 30
5.9.14 Force Arming and Ground Fault Detect Programming
Force Arming programming defines how many zones can be force armed using an arming sequence followed by
the [Bypass] key. With this entry, all violated zones (up the programmed limit) are automatically Force Armed
(bypassed). Ground Fault Detect programming determines whether or not the control panel detects a ground fault
condition.
See Section 7.2.9 Force Arming and Section 7.2.10 Ground Fault Detect Programming for glossary definitions.
Address: 2732
Data Digits:
Data Digit 1: ____ (see Table 63)
Data Digit 2: ____ (see Table 69)
Default: 1
Selections: 0 to 9 for Data Digit 1; 0 and 1 for Data Digit 2.
Table 63: Address 2732, Data Digit 1
Select Option Value
Do not allow Force Arming 0
Allow up to one zone to be Force Armed
1
Allow up to two zones to be Force Armed 2
Allow up to three zones to be Force Armed 3
Allow up to four zones to be Force Armed 4
Allow up to five zones to be Force Armed 5
Allow up to six zones to be Force Armed 6
Allow up to seven zones to be Force Armed 7
Allow up to eight zones to be Force Armed 8
Allow up to nine zones to be Force Armed 9
This limit does not apply when arming with
a keyswitch programmed with force arming
enabled.
Table 64: Address 2732, Data Digit 2
Select Option Value
Ground Fault Detect off 0
Ground Fault Detect on
1