Bosch LTC 1271 Series Manual de instalación Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
C2431M-I (4/07) 23
TXB-B ZONE PROGRAMMING PROCEDURE
A zone is a pan area, defined by a left and right limit, on the 360-degree pan plane. To program a zone with
a Bosch (Philips, Burle) controller, refer to the manual supplied with the controller and perform the
following:
IMPORTANT (Spectra and ExSite systems only): After programming a zone, always enable the zone
through the Pelco unit programming menu. Refer to the operation/programming manual supplied with the
Pelco system.
Step Procedure
1. Enter zone programming. Issue the enable zone scan command (ON 60 Enter) to
display the zone labels.
2. Set left zone limit. Position the Pelco unit at the left limit of the zone. Issue the
zone start command (ON 2# Enter) for the zone being
programmed; # is a number between 1 and 8 that represents
zones 1 through 8.
3. Set right zone limit. Position the Pelco unit at the right limit of the zone. Issue the
zone end command (OFF 2# Enter) for the zone being
programmed; # is a number between 1 and 8 that represents
zones 1 through 8.
4. Enable the zone label display. Issue the enable zone scan command (ON 60 Enter) to
display the zone labels.
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 47 48

Comentarios a estos manuales

Sin comentarios