4mm varifocal length lens with an iris range of
f1.6 to 200. The cameras shall be installed in
locations as shown on the attached security
drawings.
F. Power Supply: Provide and install Altronix model
ALTV248, or equivalent CCTV Camera and Accessory
Power Supply as required for video cameras.
2.11 ALARM SYSTEM MASTER CONTROL PANEL
A. Acceptable Manufacturers:
ADEMCO/Honeywell Vista Series with no equivalent
B. The alarm system master control panel shall have
the following functionality:
1. Eight on board hardwired zones
2. Expandable to 128 zones
3. Event log
4. Two independent partitions
5. Two on board trigger outputs
6. Two independent partitions
2.12 ALARM SYSTEM KEYPAD
A. Each alarm system keypad shall have the following
features and capabilities:
1. The keypad shall have a two-line, 32
character backlit LCD display.
2. It shall have a built-in sounder with
distinct tones for alarm and trouble
conditions.
3. Keys light on entry or key press for simple
operation.
4. Separate emergency keys.
5. User controlled brightness and volume.
6. Multiple or single area configurations.
Comentarios a estos manuales