4 | Accessory Packages for the Allegiant
outputs capable of driving up to 256 remote devices. The
LTC 8571, LTC 8572 Series provides 64 separate outputs
capable of driving up to 512 remote devices. Either “star”
or “daisy chain” wiring configurations may be used. Two
data cables for interface to Allegiant main CPU bays are
supplied (four with LTC 8570 and LTC 8572).
Unit will accept signal input either from Allegiant main CPU
bay, LTC 8568/00 output, LTC 8780 Bi-Phase output, or an
output from another LTC 8569, LTC 8570 Series or LTC
8571, LTC 8572 Series unit. Multiple units may be cascaded
to obtain additional outputs.
Electrical
Model No. Rated Voltage Voltage Range Power
LTC 8569/60,
LTC 8570/60,
LTC 8571/60,
LTC 8572/60
120 VAC, 50/60 Hz 108 to 132 12 W
LTC 8569/50,
LTC 8570/50,
LTC 8571/50,
LTC 8572/50
230 VAC, 50/60 Hz 198 to 264 12 W
Indicators
Power LED
Code LED
Connectors
Inputs Two (2), 9-pin Sub D connectors (four (4) with LTC 8570
Series and LTC 8572 Series)
Outputs Sixteen (32 on LTC 8571 and LTC 8572 Series) 6-contact
removable screw terminal blocks for code output. Maxi-
mum transmission distance is 1.5 km (5000 ft.) using
1 mm
2
(18 AWG) shielded-twisted pair (Belden 8760 or
equivalent).
AC Input 3-wire power cord with grounded plug; 1.8 m (6 ft) long
Mechanical
Construction/
Finish
Charcoal colored metal enclosure
Dimensions
(W x D x H)
445 x 318 x 89 mm (17.5 x 12.5 x 3.5 in.) Integral
mounting flanges for EIA 48 cm (19 in.) rack
Weight 5.3 kg (11.7 lb)
LTC 8770 Series Relay Units
The LTC 8770 Series are relay units that are designed to
operate with devices that generate Allegiant Bi-Phase
control code. These devices include the Allegiant series of
video matrix switcher/controllers, System4 series of
multiplexers, LTC 5136 controller series, etc. The LTC 8770
receives Bi-Phase control signals and opens or closes
relays, depending upon the desired operating mode. Each
LTC 8770 unit provides 24 individually isolated relays for
connecting to external devices. In addition, six functional
operating modes are available, including one user activated
test mode.
Electrical
Model No. Rated Voltage Voltage Range Power
LTC 8770/50 230 VAC, 50/60 Hz 198 to 264 8 W
LTC 8770/60 230 VAC, 50/60 Hz 105 to 132 8 W
Indicators Power and data transmission activity displayed using LEDs.
Device number or logical relay number indicated by a 4-
position thumbwheel switch located on the rear panel.
Connectors
Inputs One (1), 3-pin removable screw terminal connector, locat-
ed on the rear panel; communication port where Bi-Phase
commands are received
Outputs Four (4), 12-pin removable screw terminal connectors lo-
cated on the rear panel; relay contact (0.5 A at 20 VAC/DC
and a maximum resistive load of 10 VA) 36 peak volts from
either pin of the relay to ground
AC Input 3-wire power cord with grounded plug; 1.8 m (6 ft) long
Mechanical
Construction/
Finish
Steel chassis with sheet metal cover and plas-
tic bezel. Charcoal colored case.
Dimensions
(W x D x H)
223 x 280 x 40 mm
(8.77 x 11 x 1.59 in.)
Weight 1.9 kg (4.3 lb)
Optional Rack Mount Kit LTC 9101/00 (Holds 1 or 2 units)
LTC 8712 Series CONSOLE Port Expanders
The LTC 8712 Series “expands” an Allegiant system's
CONSOLE port to permit up to 4 external computing
devices to communicate with the system via RS-232
protocol. Any computing device that can normally
communicate directly with an Allegiant via its RS-232
CONSOLE port can be used with these port expanders. The
external devices can consist of PCs running the Allegiant
system's Master Control Software package, the Allegiant
Graphical User Interface (GUI), access control systems,
Allegiant series RS-232 keyboards, or other devices utilizing
the Allegiant system's Command Console Language (CCL).
The LTC 8712 Series can be used with the LTC 8100,
LTC 8200, LTC 8300, LTC 8500, LTC 8600, LTC 8800, or
LTC 8900 Series systems containing CPU software version
6.5 or higher.
Electrical
Model No. Rated Voltage Voltage Range Power
LTC 8712/60 120 VAC, 50/60 Hz 108 to 132 10 W
LTC 8712/50 230 VAC, 50/60 Hz 198 to 264 10 W
Indicators Power and data transmission activity displayed using
LEDs
Connectors
Inputs One (1), 9-pin Sub D connector; provides RS-232 inter-
face to Allegiant bay. Two-meter (6-ft) interconnect cable
to main bay supplied
Comentarios a estos manuales