Data sheet
BMA220
Page 34
BST-BMA220-DS003-08 | Revision 1.15 | August 2011 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
6.2 Digital interface modes
The BMA220 supports two different digital interfaces (SPI and I²C). The currently active general
interface is determined by the primary input PS. The configuration of interrupt engines is fully
customizable via the defined digital interface.
SPI Active Mode: The SPI interface is enabled while PS is externally connected to GND
(logic ‘0’ detected).
I
2
C Active Mode: The I²C interface is enabled while PS is externally connected to V
DDIO
(logic ‘1’ detected).